Fuel Pump Control Module Driver High Temperature
For an overview of the component/system, refer to:Fuel System Description
Component  | Description  | 
|---|---|
K111 Fuel Pump Driver Control Module  | The control module k111 supplies the fuel pump with a 3-phase voltage in order to achieve the desired pump speed required for building fuel line pressure.  | 
When the ignition is turned On, the ECM sends a 12 V signal to the control module K111 to enable the fuel pump. If the engine is not started, the control module K111 turns the fuel pump Off after 6 s.
Conditions for Running the DTCFrequency the DTC runs=Continuously—After the running conditions are met
Conditions for Setting the DTCK111 Fuel Pump Driver Control Module=Warmer than 160°C (320°F)—For greater than 1 s
Actions Taken When the DTC SetsDTCs listed in the DTC Descriptor category=Type B DTC
Conditions for Clearing the DTCDTCs listed in the DTC Descriptor category=Type B DTC
Reference InformationSchematic Reference
Connector End View ReferenceMaster Electrical Component List
Electrical Information ReferencePowertrain Diagnostic Trouble Code (DTC) Type Definitions
Scan Tool ReferenceCircuit/System VerificationRefer to:DTC P1029 or P102A-P102C
Replace the component:K111 Fuel Pump Driver Control Module
Perform the Diagnostic Repair Verification after completing the repair:Diagnostic Repair Verification
For control module replacement, programming, and setup refer to:Control Module References