Last Modified: 01-27-2025 |
6.11:8.1.0 |
Doc ID: RM100000002OT73 |
|
Model Year Start: 2025 |
Model: GR Corolla |
Prod Date Range: [09/2024 -
] |
|
Title: UC80F (AUTOMATIC TRANSMISSION / TRANSAXLE): VALVE BODY ASSEMBLY: INSPECTION; 2025 MY Corolla Corolla Hatchback GR Corolla [09/2024 - ] |
INSPECTION
PROCEDURE
1. INSPECT SOLENOID (SL) VALVE
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Solenoid (SL) valve connector terminal - Solenoid (SL) valve body
|
20°C (68°F)
|
11 to 15 Ω
|
If the result is not as specified, replace the solenoid (SL) valve.
|
|
|
*a
|
Component without harness connected
(Solenoid (SL) Valve)
|
|
|
(b) Connect a positive (+) lead from the battery to the terminal of the solenoid (SL) valve connector and a negative (-) lead to the solenoid (SL) valve body, and check that the solenoid (SL) valve moves and makes an operating sound.
NOTICE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
OK:
The solenoid (SL) valve moves and makes an operating sound.
If the result is not as specified, replace the solenoid (SL) valve.
2. INSPECT SOLENOID (SLT) VALVE
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
1 - 2
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
If the result is not as specified, replace the solenoid (SLT) valve.
|
|
|
*a
|
Component without harness connected
(Solenoid (SLT) Valve)
|
|
|
(b) Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid (SLT) valve connector, and check that the solenoid (SLT) valve moves and makes an operating sound.
NOTICE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
OK:
The solenoid (SLT) valve moves and makes an operating sound.
If the result is not as specified, replace the solenoid (SLT) valve.
3. INSPECT SOLENOID (SLU) VALVE
HINT:
Refer to Inspect Solenoid (SLT) Valve.
4. INSPECT SOLENOID (SL1) VALVE
HINT:
Refer to Inspect Solenoid (SLT) Valve.
5. INSPECT SOLENOID (SL2) VALVE
HINT:
Refer to Inspect Solenoid (SLT) Valve.
6. INSPECT SOLENOID (SL3) VALVE
HINT:
Refer to Inspect Solenoid (SLT) Valve.
7. INSPECT SOLENOID (SL4) VALVE
HINT:
Refer to Inspect Solenoid (SLT) Valve.
8. INSPECT SOLENOID (SL5) VALVE
HINT:
Refer to Inspect Solenoid (SLT) Valve.
9. INSPECT SOLENOID (SL6) VALVE
HINT:
Refer to Inspect Solenoid (SLT) Valve.
|