(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
6 (+B) - 2 (P)
|
Shift lever in P
|
Below 1 Ω
|
6 (+B) - 7 (PR)
|
Below 1 Ω
|
6 (+B) - 4 (PNB)
|
Below 1 Ω
|
6 (+B) - 1 (R), 8 (N), 3 (DB1) or 9 (DB2)
|
10 kΩ or higher
|
6 (+B) - 7 (PR)
|
Shift lever in R
|
Below 1 Ω
|
6 (+B) - 1 (R)
|
Below 1 Ω
|
6 (+B) - 2 (P), 8 (N), 3 (DB1), 9 (DB2) or 4 (PNB)
|
10 kΩ or higher
|
6 (+B) - 8 (N)
|
Shift lever in N
|
Below 1 Ω
|
6 (+B) - 4 (PNB)
|
Below 1 Ω
|
6 (+B) - 2 (P), 7 (PR), 1 (R), 3 (DB1) or 9 (DB2)
|
10 kΩ or higher
|
6 (+B) - 3 (DB1)
|
Shift lever in D or M
|
Below 1 Ω
|
6 (+B) - 9 (DB2)
|
Below 1 Ω
|
6 (+B) - 2 (P), 7 (PR), 1 (R), 8 (N) or 4 (PNB)
|
10 kΩ or higher
|
HINT:
The shift lever position sensor connector (shift lever position sensor side) does not have a terminal 5.
If the result is not as specified, replace the shift lever position sensor.
|
|
*a
|
Component without harness connected
(Shift Lever Position Sensor)
|
|
|