Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM1000000028JO3 |
Model Year Start: 2023 |
Model: GR Corolla |
Prod Date Range: [11/2022 -
] |
Title: NAVIGATION / MULTI INFO DISPLAY: NAVIGATION ANTENNA: INSPECTION; 2023 - 2025 MY Corolla Corolla Hatchback Corolla HV GR Corolla [11/2022 - ] |
INSPECTION
PROCEDURE
1. INSPECT NAVIGATION ANTENNA ASSEMBLY (w/o Manual (SOS) Switch)
(a) Check that the navigation antenna assembly cable is properly installed and does not have any sharp bends, pinching or loose connections.
(b) Current consumption check:
(1) Measure the current consumption according to the value(s) in the table below.
Standard Current:
Tester Connection
|
Condition
|
Specified Condition
|
3 (core) - 3a (shield)
|
4.2 to 5 V applied between terminals 3 and 3a
|
10 to 30 mA
|
NOTICE:
Do not apply 6 V or more between terminals 3 and 3a.
HINT:
If a stable power supply is not available, connect 4 nickel-metal hydride batteries (1.2 V each) or equivalent in series.
|
|
*a
|
Component without harness connected
(Navigation Antenna Assembly)
|
*b
|
Voltage Applied between Terminals
|
|
|
2. INSPECT NAVIGATION ANTENNA ASSEMBLY (with Manual (SOS) Switch)
(a) Check that the navigation antenna assembly cable is properly installed and does not have any sharp bends, pinching or loose connections.
(b) Current consumption check: (GPS1)
(1) Measure the current consumption according to the value(s) in the table below.
Standard Current:
Tester Connection
|
Condition
|
Specified Condition
|
3 (core) - 3a (shield)
|
4.2 to 5.0 V applied between terminals 3 and 3a
|
10 to 30 mA
|
NOTICE:
Do not apply 6 V or more between terminals 3 and 3a.
HINT:
If a stable power supply is not available, connect 4 nickel-metal hydride batteries (1.2 V each) or equivalent in series.
|
|
*a
|
Component without harness connected
(Navigation Antenna Assembly)
|
*b
|
Voltage Applied between Terminals
|
|
|
(c) Current consumption check: (GPS2)
(1) Measure the current consumption according to the value(s) in the table below.
Standard Current:
Tester Connection
|
Condition
|
Specified Condition
|
2 (core) - 2a (shield)
|
4.2 to 5.0 V applied between terminals 2 and 2a
|
10 to 30 mA
|
NOTICE:
Do not apply 6 V or more between terminals 2 and 2a.
HINT:
If a stable power supply is not available, connect 4 nickel-metal hydride batteries (1.2 V each) or equivalent in series.
|
|
*a
|
Component without harness connected
(Navigation Antenna Assembly)
|
*b
|
Voltage Applied between Terminals
|
|
|
(d) Resistance check: (Telephone Sub)
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
4 (core) - 4a (shield)
|
Always
|
9 to 11 kΩ
|
|
|
*a
|
Component without harness connected
(Navigation Antenna Assembly)
|
|
|
|