Last Modified: 05-13-2024 |
6.11:8.1.0 |
Doc ID: RM1000000028FS0 |
Model Year Start: 2023 |
Model: GR Corolla |
Prod Date Range: [11/2022 -
] |
Title: SETUP: WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL: AUTOMATIC LEARNING CHART; 2023 - 2025 MY Corolla Corolla Hatchback Corolla HV GR Corolla [11/2022 - ] |
AUTOMATIC LEARNING CHART
AUTOMATIC LEARNING PERFORMED WHEN CABLE IS DISCONNECTED / RECONNECTED TO AUXILIARY BATTERY TERMINAL (for HV Model)
When the cable is disconnected / reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
Effect/Inoperative Function when Necessary Procedure not Performed
|
Necessary Procedure
|
Link
|
Front Camera System
|
Drive the vehicle straight ahead at 15 km/h (9 mph) or more for 1 second or more.
|
|
AUTOMATIC LEARNING PERFORMED WHEN CABLE IS DISCONNECTED / RECONNECTED TO AUXILIARY BATTERY TERMINAL (for Gasoline Model)
When the cable is disconnected / reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
Effect/Inoperative Function when Necessary Procedure not Performed
|
Necessary Procedure
|
Link
|
Front Camera System
|
-
Drive the vehicle straight ahead at 35 km/h (22 mph) or more for 5 seconds or more.*1
-
Drive the vehicle straight ahead at 15 km/h (9 mph) or more for 1 second or more.*2
|
|
Learning completes when vehicle is operated normally
Effect/Inoperative Function when Necessary Procedure not Performed
|
Necessary Procedure
|
Link
|
Power Door Lock Control System
|
Perform door unlock operation with door control switch or electrical key transmitter sub-assembly switch.
|
|
|