Last Modified: 05-13-2024 |
6.11:8.1.0 |
Doc ID: RM1000000028C5M |
Model Year Start: 2023 |
Model: GR Corolla |
Prod Date Range: [11/2022 -
] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Gasoline Model with Manual Air Conditioning System): Front Window Fogging; 2023 - 2025 MY Corolla Corolla Hatchback GR Corolla [11/2022 - ] |
DESCRIPTION
If the windshield frequently fogs up even though the air conditioning system is operating, the following factors may be the cause.
Symptom
|
Factor
|
Windshield frequently fogs up
|
-
Compressor with pulley assembly malfunction
-
Refrigerant volume (low)
-
Cooler expansion valve (opened excessively)
-
Damper servo malfunction
-
Mechanical locking of damper and damper link
|
PROCEDURE
1.
|
CHECK REFRIGERANT SHORTAGE
|
(a) Prepare the vehicle according to the table below.
Measurement Condition:
Item
|
Condition
|
A/C Switch
|
On
|
Ambient Temperature*1
|
0 to 49°C (32 to 120°F)
|
Air Conditioning Air Inlet Temperature*2
|
25 to 35°C (77 to 95°F)
|
Set Temperature
|
MAX COLD
|
Recirculation/fresh Control Switch
|
Recirculation
|
Air Vent Damper Position
|
FACE
|
Blower Speed
|
HI
|
HINT:
*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.
(b) Using the GTS, check the amount of refrigerant.
Body Electrical > Air Conditioner > Utility
Tester Display
|
Refrigerant Gas Volume Check
|
NOTICE:
If the conditions for the inspection are not met, "Refrigerant incorrect" will be displayed on the GTS. Confirm the conditions of the inspection and perform the check again.
HINT:
-
If the amount of refrigerant is insufficient, "Refrigerant shortage" is displayed on the GTS and the indicator light on the A/C switch turns off.
-
When performing this inspection, a DTC will not be output even if "Refrigerant shortage" is displayed on the GTS.
Result
|
Amount of Refrigerant
|
Refrigerant shortage
|
Insufficient or leakage
|
Refrigerant correct
|
Correct
|
Refrigerant incorrect
|
Incorrect
|
OK:
"Refrigerant correct" is displayed on the GTS.
OK
|
|
|
(a) Check that the air conditioning system changes to DEF mode according to the switch operation, when the MODE switch on the air conditioning control assembly is pushed.
OK:
Air conditioning system changes to DEF mode.
|