Last Modified: 07-31-2024 6.11:8.1.0 Doc ID: RM1000000028C4O
Model Year Start: 2023 Model: GR Corolla Prod Date Range: [11/2022 -           ]
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Gasoline Model with Manual Air Conditioning System): CUSTOMIZE PARAMETERS; 2023 - 2025 MY Corolla Corolla Hatchback GR Corolla [11/2022 -        ]

CUSTOMIZE PARAMETERS

CUSTOMIZE AIR CONDITIONING SYSTEM

(a) Customizing with the GTS.

NOTICE:

  • When the customer requests a change in a function, first make sure that the function can be customized.
  • Be sure to make a note of the current settings before customizing.
  • When troubleshooting a function, first make sure that the function is set to the default setting.

HINT:

The following items can be customized.

(1) Select the setting by referring to the table below.

Air Conditioner

Tester Display

Description

Default

Setting

ECU

ECO Mode Control

This function switches ON/OFF of the controlling function of the air conditioning by ECO mode. If there is no ECO MODE switch, this customize function is not available.

$01:ON

$00:OFF,$01:ON

Air conditioning amplifier assembly

Fan Speed Increment Control

This function is defining how fast the A/C blower goes to the target air capacity when first activating the A/C.

$01:ON

$01:Short,$00:Normal,$02:Long

Air conditioning amplifier assembly

Outside Air Mode Auto Switch Function

This function switches ON/OFF of the function to switch the suction opening to the outside air mode automatically at the time of the ignition switch off.

$01:ON

$00:OFF,$01:ON

Air conditioning amplifier assembly

Evaporator Control

Function to set the evaporator control to the Automatic position (AUTO) to save power or to the coldest position (MANUAL) to dehumidify the air and to prevent the windows fogging up.

$01:ON

$00:Manual,$01:Automatic

Air conditioning amplifier assembly

Ion Generate Control

Function to generate the ion is stopped when item is OFF.

$01:ON

$00:OFF,$01:ON

Air conditioning amplifier assembly

Refrigerant Shortage Check

Function to cancel the refrigerant shortage check when item is OFF. (The verification mode is excluded.)

$01:ON

$00:OFF,$01:ON

Air conditioning amplifier assembly

S-FLOW Control Auto Function

When ignition switch is turnd to ON, ON/OFF of the function to operate in the S-FLOW Control Auto is switched.

$01:ON

$00:OFF,$01:ON

Air conditioning amplifier assembly

Ambient Temperature Adjustment

Function to control with the shifted ambient temperature against the display ambient temperature.

$00:Normal

$04:-3C,$05:-2C,$06:-1C,$00:Normal,$01:+1C,$02:+2C,$03:+3C

Air conditioning amplifier assembly