Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System): B141A11; Room Temperature Sensor Circuit Short to Ground; 2023 - 2025 MY Corolla Corolla Hatchback GR Corolla [11/2022 - ] |
DTC
|
B141A11
|
Room Temperature Sensor Circuit Short to Ground
|
DESCRIPTION
The room temp. sensor (cooler thermistor) is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the room temp. sensor (cooler thermistor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage to the room temp. sensor (cooler thermistor) and reads voltage changes due to changes in the resistance of the room temp. sensor (cooler thermistor).
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
Memory
|
B141A11
|
Room Temperature Sensor Circuit Short to Ground
|
Diagnosis Condition:
Malfunction:
-
Short (GND) in room temperature sensor circuit
Detection Time:
-
Continuously for 4 seconds or more
|
-
Room temp. sensor (cooler thermistor)
-
Harness or connector
-
Air conditioning amplifier assembly
|
Memorized
|
WIRING DIAGRAM
PROCEDURE
(a) Clear the DTCs.
Body Electrical > Air Conditioner > Clear DTCs
NEXT
|
|
|
(a) Turn the ignition switch off.
(b) Disconnect the room temp. sensor (cooler thermistor) connector.
|
|
*1
|
Room Temp. Sensor (Cooler Thermistor)
|
*2
|
Air Conditioning Amplifier Assembly
|
|
|
(c) Turn the ignition switch to ON and wait for 4 seconds or more.
(d) Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
|
Proceed to
|
B141A15 is output
|
A
|
B141A11 is output
|
B
|
B
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR))
|
(a) Disconnect the I36 room temp. sensor (cooler thermistor) connector.
(b) Disconnect the I48 air conditioning amplifier assembly connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
I36-1 or I48-5 (TR) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
I36-2 or I48-3 (SG-1) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
NG |
|