Last Modified: 05-13-2024 |
6.11:8.1.0 |
Doc ID: RM10000000277W6 |
Model Year Start: 2023 |
Model: Corolla |
Prod Date Range: [09/2022 -
] |
Title: HYBRID / BATTERY CONTROL: SERVICE PLUG GRIP: REMOVAL; 2023 - 2025 MY Corolla Corolla HV [09/2022 - ] |
REMOVAL
CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during service plug grip removal/installation are shown below.
NOTICE:
-
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.
Click here
-
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
HINT:
When the cable is disconnected / reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
Effect/Inoperative Function when Necessary Procedure not Performed
|
Necessary Procedure
|
Link
|
Front Camera System (for TMC Made)
|
Drive the vehicle straight ahead at 15 km/h (9 mph) or more for 1 second or more.
|
|
PROCEDURE
1. CHECK FOR DTC
(a) Check for DTCs.
Click here
CAUTION:
-
Confirm that DTC P0AA649 (Hybrid / EV Battery Voltage System Isolation Internal Electronic Failure), P1C7C49 (Hybrid / EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure), P1C7D49 (Hybrid / EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure), P1C7E49 (Hybrid / EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure) or P1C7F49 (Hybrid / EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure) is not output before removing or installing the HV battery assembly. If this DTC is output, perform troubleshooting for this DTC first.
-
To reduce the risk of electric shock, do not perform troubleshooting before checking for DTCs.
2. DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
Click here
3. REMOVE BATTERY SERVICE HOLE COVER
Click here
4. REMOVE SERVICE PLUG GRIP
CAUTION:
-
Be sure to wear insulated gloves.
-
Do not inspect or service the high voltage system with the service plug grip installed.
-
To reduce the risk of electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
-
To reduce the risk of electric shock, make sure to wait at least 10 minutes after removing the service plug grip to fully discharge the high voltage capacitor inside the inverter with converter assembly.
-
Keep the removed service plug grip in your pocket to prevent other technicians from accidentally installing it while you are servicing the vehicle.
NOTICE:
-
After removing the service plug grip, turning the power switch on (READY) may cause a malfunction. Do not turn the power switch on (READY) unless instructed by the repair manual.
-
Do not touch the terminals of the service plug grip.
-
If the service plug grip has been struck or dropped, replace it.
HINT:
Waiting for at least 10 minutes is required to discharge the high voltage capacitor inside the inverter with converter assembly.
(a) While wearing insulated gloves, rotate the handle of the service plug grip and remove the service plug grip as indicated by the arrows, in the order shown in the illustration.
|