Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM10000000270KE |
Model Year Start: 2023 |
Model: Corolla Hatchback |
Prod Date Range: [09/2022 - 11/2022] |
Title: M20A-FKS (COOLING): FLOW SHUTTING VALVE (for CVT): REMOVAL; 2023 MY Corolla Corolla Hatchback [09/2022 - 11/2022] |
REMOVAL
CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during flow shutting valve (water valve) removal/installation are shown below.
NOTICE:
When replacing the battery, use a new battery of the same dimensions and same capacity or more from the same class at a 20-hour rate.
HINT:
When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
Effect/Inoperative Function when Necessary Procedure not Performed
|
Necessary Procedure
|
Link
|
Front Camera System (for TMC Made)
|
Drive the vehicle straight ahead at 15 km/h (10 mph) or more for 1 second or more.
|
|
Pre-collision System (for TMMMS Made)
|
Drive the vehicle straight ahead at 35 km/h (22 mph) or more for 5 seconds or more.
|
|
Lane Tracing Assist System (for TMMMS Made)
|
Lane Departure Alert System (for TMMMS Made)
|
Learning completes when vehicle is operated normally
Effect/Inoperative Function when Necessary Procedure not Performed
|
Necessary Procedure
|
Link
|
Power Door Lock Control System
|
Perform door unlock operation with door control switch or electrical key transmitter sub-assembly switch.
|
|
PROCEDURE
1. PRECAUTION
NOTICE:
After turning the engine switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal.
Click here
2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Click here
3. REMOVE NO. 1 ENGINE UNDER COVER ASSEMBLY
Click here
4. DRAIN ENGINE COOLANT (for Fully Sealed Type)
Click here
5. DRAIN ENGINE COOLANT (for Non-Fully Sealed Type)
Click here
6. REMOVE FLOW SHUTTING VALVE (WATER VALVE)
(a) Disconnect the flow shutting valve (water valve) connector.
|
|
(b) Remove the bolt to disconnect the flow shutting valve (water valve).
|
|
(c) Slide the clip and disconnect the No. 3 water by-pass hose from the flow shutting valve (water valve).
|
|
(d) Slide the clip and disconnect the No. 4 water by-pass hose from the flow shutting valve (water valve).
|
|
|