Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for TMC Made, and Gasoline Model, with Automatic Air Conditioning System): P053515; Evaporator Temperature Sensor Circuit Short to Battery or Open; 2023 MY Corolla Corolla Hatchback GR Corolla [09/2022 - 11/2022] |
DTC
|
P053515
|
Evaporator Temperature Sensor Circuit Short to Battery or Open
|
DESCRIPTION
The evaporator temp. sensor (No. 1 cooler thermistor) is installed to the evaporator in the air conditioner unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. The resistance of the evaporator temp. sensor (No. 1 cooler thermistor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the evaporator temp. sensor (No. 1 cooler thermistor) and reads voltage changes as the resistance of the evaporator temp. sensor (No. 1 cooler thermistor) changes. This sensor is used for frost prevention.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
Memory
|
P053515
|
Evaporator Temperature Sensor Circuit Short to Battery or Open
|
Diagnosis Condition:
Malfunction:
-
Open or short (+B) in evaporator temperature sensor circuit
Detection Time:
-
Continuously for 4 seconds or more
|
-
Evaporator temp. sensor (No. 1 cooler thermistor)
-
Air conditioning harness assembly
-
Air conditioning amplifier assembly
|
Memorized
|
DTC Detection Condition Combination Table
|
Vehicle Condition
|
Pattern 1
|
Pattern 2
|
Diagnosis Condition
|
Ignition switch ON
|
○
|
○
|
Malfunction
|
Open in evaporator temperature sensor circuit
|
○
|
-
|
Short (+B) in evaporator temperature sensor circuit
|
-
|
○
|
Detection Time
|
Continuously for 4 seconds or more
|
Continuously for 4 seconds or more
|
Trip Count
|
1 trip
|
1 trip
|
HINT:
If the conditions of either of these patterns are detected, a DTC will be stored.
WIRING DIAGRAM
PROCEDURE
(a) Read the Data List according to the display on the GTS.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Evaporator Fin Thermistor
|
Evaporator temp. sensor (No. 1 cooler thermistor)
|
-327.68 to 327.67°C
|
Actual evaporator temperature displayed
|
Evaporator temp. sensor (No. 1 cooler thermistor) circuit malfunction
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Evaporator Fin Thermistor
|
OK:
The display is as specified in the normal condition column.
NG
|
|
|
2.
|
INSPECT EVAPORATOR TEMP. SENSOR (NO. 1 COOLER THERMISTOR)
|
Click here
OK
|
|
|
3.
|
INSPECT AIR CONDITIONING HARNESS ASSEMBLY (EVAPORATOR TEMP. SENSOR (NO. 1 COOLER THERMISTOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Remove the air conditioning harness assembly.
Click here
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
m2-2 - m3-6 (TE)
|
Always
|
Below 1 Ω
|
m2-1 - m3-5 (SG-3)
|
Always
|
Below 1 Ω
|
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
m3-6 (TE) - Body ground
|
Ignition switch ON
|
Below 1 V
|
m3-5 (SG-3) - Body ground
|
Ignition switch ON
|
Below 1 V
|
|