Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM1000000026Z8M |
Model Year Start: 2023 |
Model: GR Corolla |
Prod Date Range: [09/2022 - 11/2022] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for TMC Made, and Gasoline Model, with Automatic Air Conditioning System): P053511; Evaporator Temperature Sensor Circuit Short to Ground; 2023 MY Corolla Corolla Hatchback GR Corolla [09/2022 - 11/2022] |
DTC
|
P053511
|
Evaporator Temperature Sensor Circuit Short to Ground
|
DESCRIPTION
The evaporator temp. sensor (No. 1 cooler thermistor) is installed to the evaporator in the air conditioner unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. The resistance of the evaporator temp. sensor (No. 1 cooler thermistor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage to the evaporator temp. sensor (No. 1 cooler thermistor) and reads voltage changes as the resistance of the evaporator temp. sensor (No. 1 cooler thermistor) changes. This sensor is used for frost prevention.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
Memory
|
P053511
|
Evaporator Temperature Sensor Circuit Short to Ground
|
Diagnosis Condition:
Malfunction:
-
Short (GND) in evaporator temperature sensor circuit
Detection Time:
-
Continuously for 4 seconds or more
|
-
Evaporator temp. sensor (No. 1 cooler thermistor)
-
Air conditioning harness assembly
-
Air conditioning amplifier assembly
|
Memorized
|
WIRING DIAGRAM
PROCEDURE
(a) Clear the DTCs.
Body Electrical > Air Conditioner > Clear DTCs
NEXT
|
|
|
(a) Turn the ignition switch off.
(b) Disconnect the evaporator temp. sensor (No. 1 cooler thermistor) connector.
|
|
*1
|
Evaporator Temp. Sensor (No. 1 Cooler Thermistor)
|
*2
|
Air Conditioning Amplifier Assembly
|
|
|
(c) Turn the ignition switch to ON and wait for 4 seconds or more.
(d) Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
|
Proceed to
|
P053515 is output
|
A
|
P053511 is output
|
B
|
B
|
|
|
3.
|
INSPECT AIR CONDITIONING HARNESS ASSEMBLY (EVAPORATOR TEMP. SENSOR (NO. 1 COOLER THERMISTOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Remove the air conditioning harness assembly.
Click here
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
m2-2 or m3-6 (TE) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
m2-1 or m3-5 (SG-3) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
|