Last Modified: 07-31-2024 6.11:8.1.0 Doc ID: RM1000000026Z8B
Model Year Start: 2023 Model: GR Corolla Prod Date Range: [09/2022 - 11/2022]
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for TMC Made, and Gasoline Model, with Automatic Air Conditioning System): B141A11; Room Temperature Sensor Circuit Short to Ground; 2023 MY Corolla Corolla Hatchback GR Corolla [09/2022 - 11/2022]

DTC

B141A11

Room Temperature Sensor Circuit Short to Ground

DESCRIPTION

The room temp. sensor (cooler thermistor) is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the room temp. sensor (cooler thermistor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage to the room temp. sensor (cooler thermistor) and reads voltage changes due to changes in the resistance of the room temp. sensor (cooler thermistor).

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

Memory

B141A11

Room Temperature Sensor Circuit Short to Ground

Diagnosis Condition:

  • Ignition switch ON

Malfunction:

  • Short (GND) in room temperature sensor circuit

Detection Time:

  • Continuously for 4 seconds or more
  • Room temp. sensor (cooler thermistor)
  • Harness or connector
  • Air conditioning amplifier assembly

Memorized

WIRING DIAGRAM

PROCEDURE

1.

CLEAR DTC

(a) Clear the DTCs.

Body Electrical > Air Conditioner > Clear DTCs

NEXT

2.

CHECK FOR DTC

(a) Turn the ignition switch off.

(b) Disconnect the room temp. sensor (cooler thermistor) connector.

*1

Room Temp. Sensor (Cooler Thermistor)

*2

Air Conditioning Amplifier Assembly

(c) Turn the ignition switch to ON and wait for 4 seconds or more.

(d) Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes

Result

Proceed to

B141A15 is output

A

B141A11 is output

B

A

REPLACE ROOM TEMP. SENSOR (COOLER THERMISTOR)

B

3.

CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR))

(a) Disconnect the I36 room temp. sensor (cooler thermistor) connector.

(b) Disconnect the I48 air conditioning amplifier assembly connector.

(c) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

I36-1 or I48-5 (TR) - Other terminals and body ground

Always

10 kΩ or higher

I36-2 or I48-3 (SG-1) - Other terminals and body ground

Always

10 kΩ or higher

OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR