Last Modified: 05-13-2024 |
6.11:8.1.0 |
Doc ID: RM1000000026PXW |
Model Year Start: 2023 |
Model: Corolla HV |
Prod Date Range: [09/2022 -
] |
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY with PA10): P0E5111,P0E5115,P0E511F; DC/DC Converter Current Sensor Circuit Short to Ground; 2023 - 2025 MY Corolla HV [09/2022 - ] |
DTC
|
P0E5111
|
DC/DC Converter Current Sensor Circuit Short to Ground
|
DTC
|
P0E5115
|
DC/DC Converter Current Sensor Circuit Short to Battery or Open
|
DTC
|
P0E511F
|
DC/DC Converter Current Sensor Circuit Intermittent
|
DESCRIPTION
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
Note
|
P0E5111
|
DC/DC Converter Current Sensor Circuit Short to Ground
|
Short to ground detected in reactor current sensor circuit
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P0E53
|
P0E5115
|
DC/DC Converter Current Sensor Circuit Short to Battery or Open
|
Open or short to +B detected in reactor current sensor circuit
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P0E54
|
P0E511F
|
DC/DC Converter Current Sensor Circuit Intermittent
|
Short to ground, open or short to +B detected in reactor current sensor circuit when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
SAE Code:
P0E55
|
MONITOR DESCRIPTION
If the motor generator control ECU detects an open or short in the DC/DC converter current sensor circuit, it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs
|
P0E53 (INF P0E5111): DC/DC Converter Current Sensor Range "A" check (Low voltage)
P0E54 (INF P0E5115): DC/DC Converter Current Sensor Range "A" check (High voltage)
|
Required sensors/components
|
DC/DC converter current sensor
|
Frequency of operation
|
Continuous
|
Duration
|
TMC's intellectual property
|
MIL operation
|
Immediately
|
Sequence of operation
|
None
|
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored
|
TMC's intellectual property
|
Other conditions belong to TMC's intellectual property
|
-
|
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property
|
-
|
COMPONENT OPERATING RANGE
Motor generator control ECU
|
DTC P0E53 (INF P0E5111) is not detected
DTC P0E54 (INF P0E5115) is not detected
|
CONFIRMATION DRIVING PATTERN
HINT:
-
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the ignition switch off and wait for 2 minutes or more.
-
Turn the ignition switch to ON and wait for 5 seconds or more. [*1]
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
-
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE, perform the normal judgment procedure again.
CAUTION / NOTICE / HINT
CAUTION:
Refer to the precautions before inspecting high voltage circuit.
Click here
PROCEDURE
1.
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
|
Click here
NEXT |
|
COMPLETED
|
|