Microcomputer malfunction
|
Motor generator control system
|
P0A1A47
|
Generator Control Module Watchdog / Safety MC Failure
|
P0A1A49
|
Control Module Internal Electronic Failure
|
P0A1B47
|
Drive Motor "A" Control Module Watchdog / Safety MC Failure
|
P1C2A1C
|
Generator A/D Converter Circuit Circuit Voltage Out of Range
|
P1C2A49
|
Generator A/D Converter Circuit Internal Electronic Failure
|
P1C2A71
|
Generator A/D Converter Circuit Actuator Stuck
|
P1C2B1C
|
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
|
P1C2B49
|
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
|
P1C2B71
|
Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck
|
P313383
|
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect
|
P313386
|
Communication Error from Generator to Drive Motor "A" Signal Invalid
|
P313387
|
Communication Error from Generator to Drive Motor "A" Missing Message
|
Hybrid control system
|
P0A1B49
|
Drive Motor "A" Control Module Internal Electronic Failure
|
Power source circuit malfunction
|
Motor generator control system
|
P06B01C
|
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
P06D61C
|
Generator Control Module Offset Power Circuit Voltage Out of Range
|
Communication malfunction
|
Motor generator control system
|
U11B387
|
Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message
|
Sensor and actuator circuit malfunction
|
Motor generator control system
|
P0A3F16
|
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
|
P0A3F21
|
Drive Motor "A" Position Sensor Signal Amplitude < Minimum
|
P0A3F22
|
Drive Motor "A" Position Sensor Signal Amplitude > Maximum
|
P0C5013
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Open
|
P0C5016
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold
|
P0C5017
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold
|
P0C5A13
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Open
|
P0C5A16
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold
|
P0C5A17
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold
|
P0D2D16
|
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold
|
P0D2D17
|
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
|
P1CAD49
|
Drive Motor "A" Position Sensor Internal Electronic Failure
|
P1CB038
|
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
|
System malfunction
|
Motor generator control system
|
P0A7873
|
Drive Motor "A" Inverter Actuator Stuck Closed
|