P06B01C
|
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P06B0
|
P06B31C
|
Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P06B3
|
P06B31F
|
Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Intermittent
|
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
SAE Code:
P1C61
|
P0A1A49
|
Generator Control Module Internal Electronic Failure
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P0A1A
|
P0A1B47
|
Drive Motor "A" Control Module Watchdog / Safety MC Failure
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P0A1B
|
P0A1B49
|
Drive Motor "A" Control Module Internal Electronic Failure
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P0A1B
|
P0A1C49
|
Drive Motor "B" Control Module Internal Electronic Failure
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P0A1C
|
P1C2A1C
|
Generator A/D Converter Circuit Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P1C2A
|
P1C2A71
|
Generator A/D Converter Circuit Actuator Stuck
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P1C2A
|
P1C2B1C
|
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P1C2B
|
P1C2B49
|
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P1C2B
|
P1C2B71
|
Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P1C2B
|
P1C2C1C
|
Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P1C2C
|
P1C2C71
|
Drive Motor "B" Control Module A/D Converter Circuit Actuator Stuck
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P1C2C
|
P1C601F
|
Generator Control Module Position Sensor REF Power Source Circuit Intermittent
|
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
SAE Code:
P1C60
|
P1C621F
|
Generator Control Module Offset Power Circuit Intermittent
|
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
SAE Code:
P1C62
|
P26DF1C
|
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P26DF
|
P26DF1F
|
Generator Control Module Position Sensor REF Power Source Circuit Intermittent
|
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
SAE Code:
P19F7
|
P310A1F
|
Communication Error from Drive Motor "B" to Drive Motor "A" Circuit Intermittent
|
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
SAE Code:
P310A
|
P310A83
|
Communication Error from Drive Motor "B" to Drive Motor "A" Value of Signal Protection Calculation Incorrect
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P310A
|
P310A86
|
Communication Error from Drive Motor "B" to Drive Motor "A" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P310A
|
P310A87
|
Communication Error from Drive Motor "B" to Drive Motor "A" Missing Message
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P310A
|
P310B1F
|
Communication Error from Drive Motor "A" to Drive Motor "B" Circuit Intermittent
|
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
SAE Code:
P310B
|
P310B83
|
Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P310B
|
P310B86
|
Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P310B
|
P310B87
|
Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P310B
|
P313383
|
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P3133
|
P313386
|
Communication Error from Generator to Drive Motor "A" Signal Invalid
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P3133
|
P313387
|
Communication Error from Generator to Drive Motor "A" Missing Message
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P3133
|
P313483
|
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P3134
|
P313486
|
Communication Error from Drive Motor "A" to Generator Signal Invalid
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P3134
|
P313487
|
Communication Error from Drive Motor "A" to Generator Missing Message
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P3134
|
P32BF1F
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Circuit Intermittent
|
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
SAE Code:
P32BF
|
P32BF83
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Value of Signal Protection Calculation Incorrect
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P32BF
|
P32BF86
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P32BF
|
P32BF87
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Missing Message
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P32BF
|
P32CF1F
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Circuit Intermittent
|
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
SAE Code:
P32CF
|
P32CF83
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P32CF
|
P32CF86
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P32CF
|
P32CF87
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
SAE Code:
P32CF
|