Last Modified: 05-13-2024 |
6.11:8.1.0 |
Doc ID: RM1000000026PVT |
Model Year Start: 2023 |
Model: Corolla HV |
Prod Date Range: [09/2022 -
] |
Title: HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for LITHIUM-ION BATTERY with PA10): P253314; Ignition Switch On/Start Position Circuit Low Circuit Short to Ground or Open; 2023 - 2025 MY Corolla HV [09/2022 - ] |
DTC
|
P253314
|
Ignition Switch On/Start Position Circuit Low Circuit Short to Ground or Open
|
DTC SUMMARY
The hybrid vehicle control ECU stores a DTC when there is no auxiliary battery voltage to the IGR terminal even though there is auxiliary battery voltage to the IGP terminal.
DESCRIPTION
When the ignition switch is turned to ON, the auxiliary battery power source is supplied to the IGP and IGR terminals of the hybrid vehicle control ECU. When the ignition switch is off, the auxiliary battery power source is cut off.
When the ignition switch is turned off during driving, the auxiliary battery power source supplied to the IGP terminal is cut off. However, the auxiliary battery power source supplied to the IGR terminal is supplied until the vehicle is stopped and the ignition switch is turned off.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
Note
|
P253314
|
Ignition Switch On/Start Position Circuit Low Circuit Short to Ground or Open
|
Short to ground or open in IGR terminal circuit.
(2 trip detection logic)
|
-
Power distribution box assembly
-
Wire harness or connector
-
Hybrid vehicle control ECU
|
Does not come on
|
Master Warning: Does not come on
|
SAE Code:
P2534
|
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the ignition switch off and wait for at least 30 seconds.
-
Turn the ignition switch to ON (READY) and wait for 1 minute or more.
-
Enter the following menus: Powertrain / Engine / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE, perform driving pattern again.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
Before replacing the certification ECU (smart key ECU assembly), refer to Registration.
Click here
PROCEDURE
1.
|
READ VALUE USING GTS (IGR)
|
(a) Read the Data List.
Powertrain > Hybrid Control > Data List
Standard:
GTS Display
|
Switch Condition
|
Specified Condition
|
IGR
|
Ignition switch ON
|
ON
|
NG
|
|
|
2.
|
CHECK TERMINAL VOLTAGE (IGR VOLTAGE)
|
(a) Turn the ignition switch to ON.
(b) Measure the voltage according to the value(s) in the table below.
*a
|
Component with harness connected
(Hybrid Vehicle Control ECU)
|
-
|
-
|
Standard Voltage:
Tester Connection
|
Switch Condition
|
Specified Condition
|
A161-8 (IGR) - I3-1 (E1)
|
Ignition switch ON
|
11 to 14 V
|
(c) Turn the ignition switch off.
NG
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (POWER DISTRIBUTION BOX ASSEMBLY - HYBRID VEHICLE CONTROL ECU)
|
(a) Disconnect the hybrid vehicle control ECU connector.
(b) Disconnect the power distribution box assembly connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
Tester Connection
|
Condition
|
Specified Condition
|
8F-22 - A161-8 (IGR)
|
Always
|
Below 1 Ω
|
Standard Resistance (Check for Short):
Tester Connection
|
Condition
|
Specified Condition
|
8F-22 or A161-8 (IGR) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
(d) Reconnect the power distribution box assembly connector.
(e) Reconnect the hybrid vehicle control ECU connector.
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
4.
|
CHECK HARNESS AND CONNECTOR (POWER DISTRIBUTION BOX ASSEMBLY - BODY GROUND)
|
(a) Disconnect the power distribution box assembly connectors.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
8A-8 - Body ground
|
Always
|
Below 1 Ω
|
8D-8 - Body ground
|
Always
|
Below 1 Ω
|
(c) Reconnect the power distribution box assembly connectors.
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|