(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
10 (+B) - 12 (E)
|
Switch pushed
|
Below 50 Ω
|
10 (+B) - 12 (E)
|
Switch not pushed
|
10 kΩ or higher
|
HINT:
If the result is not as specified, replace the brake hold switch (electric parking brake switch assembly).
|
|
*a
|
Component without harness connected
(Brake Hold Switch (Electric Parking Brake Switch Assembly))
|
|
|