Foot/DEF Automatic Blow Up Function
|
When air outlet was chosen in DEF (defroster), function to automatically increase air capacity is changed.
|
$01:ON
|
$00:OFF,$01:ON
|
Air conditioning amplifier assembly
|
Foot/DEF Auto Mode
|
Function to turn the air flow from Foot/DEF ON automatically when AUTO MODE is ON.
|
$01:ON
|
$00:OFF,$01:ON
|
Air conditioning amplifier assembly
|
Efficient Ventilation Mode
|
Function to automatically change ambient air induction and room circulation is set.*
|
$01:ON
|
$00:OFF,$01:ON
|
Air conditioning amplifier assembly
|
ECO Mode Control
|
This function switches ON/OFF of the controlling function of the air conditioning by ECO mode. If there is no ECO MODE switch, this customize function is not available.
|
$01:ON
|
$00:OFF,$01:ON
|
Air conditioning amplifier assembly
|
Fan Speed Increment Control
|
This function is defining how fast the A/C blower goes to the target air capacity when first activating the A/C.
|
$01:ON
|
$01:Short,$00:Normal,$02:Long
|
Air conditioning amplifier assembly
|
Outside Air Mode Auto Switch Function
|
This function switches ON/OFF of the function to switch the suction opening to the outside air mode automatically at the time of the ignition switch off.
|
$01:ON
|
$00:OFF,$01:ON
|
Air conditioning amplifier assembly
|
Evaporator Control
|
Function to set the evaporator control to the Automatic position (AUTO) to save power or to the coldest position (MANUAL) to dehumidify the air and to prevent the windows fogging up.
|
$01:ON
|
$00:Manual,$01:Automatic
|
Air conditioning amplifier assembly
|
Noise and Vibration Reduction
|
Function to change speed of the compressor when item is ON.
|
$00:OFF
|
$00:OFF,$01:ON
|
Air conditioning amplifier assembly
|
Ion Generate Control
|
Function to generate the ion is stopped when item is OFF.
|
$01:ON
|
$00:OFF,$01:ON
|
Air conditioning amplifier assembly
|
Set Temperature Shift
|
Function to control with the shifted temperature against the display temperature.
|
$00:Normal
|
$05:-2C,$06:-1C,$00:Normal,$01:+1C,$02:+2C
|
Air conditioning amplifier assembly
|
Refrigerant Shortage Check
|
Function to cancel the refrigerant shortage check when item is OFF. (The verification mode is excluded.)
|
$01:ON
|
$00:OFF,$01:ON
|
Air conditioning amplifier assembly
|
S-FLOW Control Auto Function
|
When ignition switch is turnd to ON, ON/OFF of the function to operate in the S-FLOW Control Auto is switched.
|
$01:ON
|
$00:OFF,$01:ON
|
Air conditioning amplifier assembly
|
A/C Auto Switch Mode
|
Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF.
|
$01:ON
|
$00:OFF,$01:ON
|
Air conditioning amplifier assembly
|
Ambient Temperature Adjustment
|
Function to control with the shifted ambient temperature against the display ambient temperature.
|
$00:Normal
|
$04:-3C,$05:-2C,$06:-1C,$00:Normal,$01:+1C,$02:+2C,$03:+3C
|