C059749
|
Brake System Control Module "A" Internal Electronic Failure
|
When the +BS terminal voltage is from 9.5 to 17.4 V and the solenoid relay is ON, the relay contact is ON and the pump motor is in a low voltage state continuously for 0.1 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C12A51C
|
Left Front Wheel ABS Hold Solenoid Control Circuit Voltage Out of Range
|
Any of the following is detected:
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SFLH) outputs OFF, open circuit continues for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SFLH) outputs OFF, current is maintained for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SFLH) outputs ON, overcurrent continues for 0.1 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SFLH) outputs ON, open circuit continues for 0.05 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C12B01C
|
Left Front Wheel ABS Release Solenoid Control Circuit Voltage Out of Range
|
Either of the following is detected:
-
When the +BS terminal voltage is 17.4 V or less while reduction solenoid (SFLR) outputs OFF, reduction solenoid (SFLR) is ON continuously for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while reduction solenoid (SFLR) outputs ON, reduction solenoid (SFLR) is OFF continuously for 0.05 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C12BB1C
|
Right Front Wheel ABS Hold Solenoid Control Circuit Voltage Out of Range
|
Any of the following is detected:
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SFRH) outputs OFF, open circuit continues for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SFRH) outputs OFF, current is maintained for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SFRH) outputs ON, overcurrent continues for 0.1 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SFRH) outputs ON, open circuit continues for 0.05 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C12C61C
|
Right Front Wheel ABS Release Solenoid Control Circuit Voltage Out of Range
|
Either of the following is detected:
-
When the +BS terminal voltage is 17.4 V or less while reduction solenoid (SFRR) outputs OFF, reduction solenoid (SFRR) is ON continuously for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while reduction solenoid (SFRR) outputs ON, reduction solenoid (SFRR) is OFF continuously for 0.05 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C12D11C
|
Left Rear Wheel ABS Hold Solenoid Control Circuit Voltage Out of Range
|
Any of the following is detected:
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SRLH) outputs OFF, open circuit continues for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SRLH) outputs OFF, current is maintained for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SRLH) outputs ON, overcurrent continues for 0.1 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SRLH) outputs ON, open circuit continues for 0.05 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C12DC1C
|
Left Rear Wheel ABS Release Solenoid Control Circuit Voltage Out of Range
|
Either of the following is detected:
-
When the +BS terminal voltage is 17.4 V or less while reduction solenoid (SRLR) outputs OFF, reduction solenoid (SRLR) is ON continuously for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while reduction solenoid (SRLR) outputs ON, reduction solenoid (SRLR) is OFF continuously for 0.05 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C12E71C
|
Right Rear Wheel ABS Hold Solenoid Control Circuit Voltage Out of Range
|
Any of the following is detected:
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SRRH) outputs OFF, open circuit continues for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SRRH) outputs OFF, current is maintained for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SRRH) outputs ON, overcurrent continues for 0.1 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while holding solenoid (SRRH) outputs ON, open circuit continues for 0.05 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C12F21C
|
Right Rear Wheel ABS Release Solenoid Control Circuit Voltage Out of Range
|
Either of the following is detected:
-
When the +BS terminal voltage is 17.4 V or less while reduction solenoid (SRRR) outputs OFF, reduction solenoid (SRRR) is ON continuously for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while reduction solenoid (SRRR) outputs ON, reduction solenoid (SRRR) is OFF continuously for 0.05 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C12F662
|
Left Front Wheel ABS Hold Solenoid / Right Front Wheel ABS Hold Solenoid Signal Compare Failure
|
A difference in holding solenoid (SFLH) and holding solenoid (SFRH) output accuracy continues for 0.2 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C12F762
|
Left Rear Wheel ABS Hold Solenoid / Right Rear Wheel ABS Hold Solenoid Signal Compare Failure
|
A difference in holding solenoid (SRLH) and holding solenoid (SRRH) output accuracy continues for 0.2 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C13BF62
|
Brake Pressure Control Solenoid A/B Signal Compare Failure
|
A difference in master cylinder cut solenoid (SM1) and master cylinder cut solenoid (SM2) output accuracy continues for 0.2 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C13C01C
|
Brake Pressure Control Solenoid "A" Control Circuit Voltage Out of Range
|
Any of the following is detected:
-
When the +BS terminal voltage is 17.4 V or less while master cylinder cut solenoid (SM1) is on, overcurrent continues for 0.1 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while master cylinder cut solenoid (SM1) is off, an open circuit continues for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while master cylinder cut solenoid (SM1) is on, an open circuit continues for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while master cylinder cut solenoid (SM1) is off, current continues to be applied for 0.05 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|
C13C91C
|
Brake Pressure Control Solenoid "B" Control Circuit Voltage Out of Range
|
Any of the following is detected:
-
When the +BS terminal voltage is 17.4 V or less while master cylinder cut solenoid (SM2) is on, overcurrent continues for 0.1 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while master cylinder cut solenoid (SM2) is off, an open circuit continues for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while master cylinder cut solenoid (SM2) is on, an open circuit continues for 0.05 seconds or more.
-
When the +BS terminal voltage is 17.4 V or less while master cylinder cut solenoid (SM2) is off, current continues to be applied for 0.05 seconds or more.
|
Skid control ECU (Brake actuator assembly)
|