Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM1000000025R3X |
Model Year Start: 2023 |
Model: GR Corolla |
Prod Date Range: [09/2022 - 11/2022] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (except TMC Made, and Gasoline Model, with Manual Air Conditioning System for Electrical Control Type): Air Vent cannot be Switched; 2023 MY Corolla Corolla Hatchback GR Corolla [09/2022 - 11/2022] |
Air Vent cannot be Switched
|
DESCRIPTION
If the air outlet mode does not change even though the air outlet display changes, the following factors may be the cause.
Symptom
|
Factor
|
Air outlet mode cannot be changed
-
(Air outlet display changes)
|
-
No. 1 air conditioning radiator damper servo sub-assembly malfunction
-
Damper link disconnection
-
Air conditioner unit assembly malfunction
|
PROCEDURE
1.
|
CHECK NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
|
(a) Check that the No. 1 air conditioning radiator damper servo sub-assembly is installed correctly.
OK:
The No. 1 air conditioning radiator damper servo sub-assembly is installed correctly.
OK
|
|
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Trouble Codes.
(e) Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
|
Proceed to
|
B1443 is not output
|
A
|
B1443 is output
|
B
|
|