Last Modified: 01-27-2025 |
6.11:8.1.0 |
Doc ID: RM1000000025R3T |
|
Model Year Start: 2023 |
Model: GR Corolla |
Prod Date Range: [09/2022 - 11/2022] |
|
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (except TMC Made, and Gasoline Model, with Manual Air Conditioning System for Electrical Control Type): Weak Blower Output; 2023 MY Corolla Corolla Hatchback GR Corolla [09/2022 - 11/2022] |
DESCRIPTION
If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following factors may be the cause.
|
Symptom
|
Factor
|
-
Airflow volume is constantly low
-
Airflow volume sometimes becomes low
|
-
Blower motor with fan sub-assembly malfunction
-
Clogged clean air filter
-
Clogged No. 1 cooler evaporator sub-assembly or heater radiator unit sub-assembly fins
-
No. 1 cooler thermistor malfunction
-
Aspirator not connected properly
|
PROCEDURE
|
1.
|
CHECK AIR CONDITIONING SYSTEM
|
(a) Operate the blower switch with the following conditions met and check that the airflow volume changes.
|
Blower Speed
|
Condition
|
|
LO → HI
|
-
Temperature setting: MAX COLD
-
Air outlet mode: FACE
-
A/C switch: Off
|
OK:
Airflow volume increases.
|
OK
|
|
|
|
2.
|
CHECK CLEAN AIR FILTER
|
(a) Visually check the clean air filter.
Click here
OK:
The clean air filter is not dirty or clogged.
|
OK
|
|
|
|
3.
|
CHECK NO. 1 COOLER THERMISTOR
|
(a) Check the installation condition of the No. 1 cooler thermistor.
OK:
The No. 1 cooler thermistor is installed correctly.
|
OK
|
|
|
(a) Check the installation condition of the aspirator.
OK:
The aspirator is installed correctly.
|