Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM1000000025R3T |
Model Year Start: 2023 |
Model: GR Corolla |
Prod Date Range: [09/2022 - 11/2022] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (except TMC Made, and Gasoline Model, with Manual Air Conditioning System for Electrical Control Type): Weak Blower Output; 2023 MY Corolla Corolla Hatchback GR Corolla [09/2022 - 11/2022] |
DESCRIPTION
If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following factors may be the cause.
Symptom
|
Factor
|
-
Airflow volume is constantly low
-
Airflow volume sometimes becomes low
|
-
Blower motor with fan sub-assembly malfunction
-
Clogged clean air filter
-
Clogged No. 1 cooler evaporator sub-assembly or heater radiator unit sub-assembly fins
-
No. 1 cooler thermistor malfunction
-
Aspirator not connected properly
|
PROCEDURE
1.
|
CHECK AIR CONDITIONING SYSTEM
|
(a) Operate the blower switch with the following conditions met and check that the airflow volume changes.
Blower Speed
|
Condition
|
LO → HI
|
-
Temperature setting: MAX COLD
-
Air outlet mode: FACE
-
A/C switch: Off
|
OK:
Airflow volume increases.
OK
|
|
|
2.
|
CHECK CLEAN AIR FILTER
|
(a) Visually check the clean air filter.
Click here
OK:
The clean air filter is not dirty or clogged.
OK
|
|
|
3.
|
CHECK NO. 1 COOLER THERMISTOR
|
(a) Check the installation condition of the No. 1 cooler thermistor.
OK:
The No. 1 cooler thermistor is installed correctly.
OK
|
|
|
(a) Check the installation condition of the aspirator.
OK:
The aspirator is installed correctly.
|