Last Modified: 07-31-2024 6.11:8.1.0 Doc ID: RM1000000025R3O
Model Year Start: 2023 Model: GR Corolla Prod Date Range: [09/2022 - 11/2022]
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (except TMC Made, and Gasoline Model, with Manual Air Conditioning System for Electrical Control Type): A/C Switch Indicator does not Turn On; 2023 MY Corolla Corolla Hatchback GR Corolla [09/2022 - 11/2022]

A/C Switch Indicator does not Turn On

DESCRIPTION

If none of the switch indicators on the air conditioning control assembly illuminate, the following factors may be the cause.

Symptom

Factor

A/C switch indicator does not illuminate

  • Air conditioning amplifier assembly malfunction
  • Air conditioning control assembly malfunction
  • A/C switch malfunction
  • A/C switch indicator malfunction (including when indicator turned off without switch operation)
  • Servo motor initialization (incomplete)
  • Mechanical locking of damper and damper link
  • Refrigerant pressure is extremely low
  • Low detected ambient temperature (including thermistor assembly malfunction)

PROCEDURE

1.

CHECK MALFUNCTION STATUS

(a) Check the malfunction status of switch indicators on the air conditioning control assembly.

Result

Proceed to

Indicators are not always illuminated

A

Indicators are not illuminated only immediately after starting the engine

B

B

GO TO INITIALIZATION

A

2.

READ VALUE USING TECHSTREAM

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn the Techstream on.

(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.

(e) Read the Data List according to the display on the Techstream.

Body Electrical > Air Conditioner > Data List

Tester Display

Measurement Item

Range

Normal Condition

Diagnostic Note

Ambient Temp Sensor

Thermistor assembly

Min.: -23.30°C (-9.94°F)

Max.: 65.95°C (150.71°F)

Actual ambient temperature displayed

Thermistor assembly circuit malfunction

  • When open circuit: -23.30°C (-9.94°F)
  • When short circuit: 65.95°C (150.71°F)

Body Electrical > Air Conditioner > Data List

Tester Display

Ambient Temp Sensor

OK:

The value displayed is 0°C (32°F) or higher.

OK

INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

NG

GO TO OTHER DIAGNOSIS PROCEDURE (Ambient Temperature Display System)