Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (except TMC Made, and Gasoline Model, with Automatic Air Conditioning System): B1423; Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure; 2023 MY Corolla Corolla Hatchback GR Corolla [09/2022 - 11/2022] |
DTC
|
B1423
|
Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure
|
DESCRIPTION
This DTC is stored if refrigerant pressure on the high pressure side is extremely low (196 kPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2812 kPaG (28.7 kgf/cm2, 408 psi) or more). The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
Memory
|
B1423
|
Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure
|
-
Open or short in air conditioner pressure sensor circuit
-
Refrigerant pressure on high pressure side is extremely low (196 kPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2812 kPaG (28.7 kgf/cm2, 408 psi) or more)
|
-
Air conditioner pressure sensor
-
Harness or connector
-
Air conditioning amplifier assembly
-
Cooler expansion valve (blocked, stuck)
-
Cooler condenser assembly (blocked, deterioration of cooling capacity due to dirt)
-
Cooler dryer (moisture in the refrigerant cycle cannot be absorbed)
-
Cooling fan system (cooler condenser assembly cannot be cooled down)
-
Air conditioning system (leaks, blocked)
-
Refrigerant volume (excessive, low)
|
-
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
-
Be sure to check the refrigerant volume first when this DTC is output because this DTCcan also be stored if there is no refrigerant in the cycle.
Click here
-
If DTC B1423 and B14B8 are output at the same time, troubleshoot for DTC B14B8 first.
Click here
HINT:
Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCsagain.
PROCEDURE
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
|
Proceed to
|
B14B8 is not output
|
A
|
B14B8 is output
|
B
|
A
|
|
|
2.
|
COMPARE REFRIGERANT GAS PRESSURE VALUES SHOWN ON TECHSTREAM AND MANIFOLD GAUGE SET
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Regulator Pressure Sensor
|
Air conditioner pressure sensor
|
Min.: -456.68 kPaG
Max.: 3294.37 kPaG
|
Actual refrigerant pressure displayed
|
-
Refrigerant line (gas leak etc.)
-
Air conditioner pressure sensor circuit malfunction
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Regulator Pressure Sensor
|
(f) Install a manifold gauge set.
Click here
(g) Compare the values displayed in the Data List and on the manifold gauge set.
Result
|
Proceed to
|
Data List value and manifold gauge set value do not match and Data List value: 196 kPaG (2.0 kgf/cm2, 28 psi) or less
|
A
|
Data List value and manifold gauge set value do not match and Data List value: 2812 kPaG (28.7 kgf/cm2, 408 psi) or more
|
B
|
Data List value matches manifold gauge set value
|
C
|
A
|
|
|
3.
|
READ VALUE USING TECHSTREAM (REGULATOR PRESSURE SENSOR)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Regulator Pressure Sensor
|
Air conditioner pressure sensor
|
Min.: -456.68 kPaG
Max.: 3294.37 kPaG
|
Actual refrigerant pressure displayed
|
-
Refrigerant line (gas leak etc.)
-
Air conditioner pressure sensor circuit malfunction
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Regulator Pressure Sensor
|
OK:
Disconnecting the A61 connector of the air conditioner pressure sensor causes the Data List value to change.
Result
|
Proceed to
|
Regulator pressure sensor value changes
|
A
|
Regulator pressure sensor value does not change
|
B
|
A
|
|
|
4.
|
CHECK TERMINAL VOLTAGE (AIR CONDITIONER PRESSURE SENSOR)
|
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
A61-3 (+) - Body ground
|
Ignition switch ON
|
4.75 to 5.25 V
|
|
|
*a
|
Front view of wire harness connector
(to Air Conditioner Pressure Sensor)
|
|
|
NG
|
|
|
5.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the I48 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A61-3 (+) - I48-11 (S5-3)
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
6.
|
CHECK TERMINAL VOLTAGE (AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
A61-2 (PR) - Body ground
|
Ignition switch ON
|
3.0 to 5.25 V
|
|
|
*a
|
Front view of wire harness connector
(to Air Conditioner Pressure Sensor)
|
|
|
NG
|
|
|
7.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the I48 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A61-2 (PR) or I48-6 (PRE) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
8.
|
CHECK HARNESS AND CONNECTOR
|
(a) Disconnect the A61 air conditioner pressure sensor connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A61-1 (-) - Body ground
|
Always
|
Below 1 Ω
|
OK
|
|
|
9.
|
CHECK TERMINAL VOLTAGE
|
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
A61-2 (PR) - Body ground
|
Ignition switch ON
|
3.0 to 5.25 V
|
|
|
*a
|
Front view of wire harness connector
(to Air Conditioner Pressure Sensor)
|
|
|
Result
|
Proceed to
|
5.25 V or higher
|
A
|
3.0 to 5.25 V
|
B
|
Below 3.0 V
|
C
|
A
|
|
|
10.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the I48 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A61-2 (PR) or I48-6 (PRE) - Other terminals
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
11.
|
CHECK INTERNAL CIRCUIT RESISTANCE (AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A61-3 (+) - A61-2 (PR)
|
Ignition switch off
|
180 to 220 kΩ
|
HINT:
After turning the ignition switch off, wait at least 30 seconds before performing the measurement.
NG
|
|
|
12.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the I48 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A61-2 (PR) or I48-6 (PRE) - A61-3 (+) or I48-11 (S5-3)
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
13.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the I48 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A61-2 (PR) - I48-6 (PRE)
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
14.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the I48 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A61-1 (-) - I48-15 (SG-4)
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|