Last Modified: 05-13-2024 |
6.11:8.1.0 |
Doc ID: RM1000000025JBV |
Model Year Start: 2023 |
Model: GR Corolla |
Prod Date Range: [09/2022 - 11/2022] |
Title: METER / GAUGE / DISPLAY: METER / GAUGE SYSTEM (except 12.3 Inch Display): Engine Oil Pressure Switch Circuit; 2023 MY Corolla Corolla Hatchback Corolla HV GR Corolla [09/2022 - 11/2022] |
Engine Oil Pressure Switch Circuit
|
DESCRIPTION
The combination meter assembly and engine oil pressure switch assembly are connected via direct line. The combination meter assembly determines the engine oil pressure based on the engine oil pressure switch signal.
HINT:
-
The combination meter assembly receives various signals in order to output warnings from the ECM and hybrid vehicle control ECU via CAN communication.
-
The combination meter assembly operates the following to output oil pressure warnings:
-
Engine oil pressure warning buzzer
-
Engine oil pressure warning message on multi-information display
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
-
When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.
-
The following troubleshooting procedure is based on the assumption that the SFI system and hybrid control system are normal. Confirm that the SFI system and hybrid control system are not malfunctioning before performing the following procedure.
SFI system (for 2ZR-FXE): Click here
SFI system (for 2ZR-FAE): Click here
Hybrid control system: Click here
-
for TMC Made
When replacing the combination meter assembly, update the ECU security key.
Click here
PROCEDURE
1.
|
INSPECT ENGINE OIL PRESSURE SWITCH ASSEMBLY
|
for 2ZR-FXE: Click here
for 2ZR-FAE: Click here
NG |
|
REPLACE ENGINE OIL PRESSURE SWITCH ASSEMBLY
for 2ZR-FXE: Click here
for 2ZR-FAE: Click here
|
OK
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (ENGINE OIL PRESSURE SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY)
|
(a) Disconnect the I5 combination meter assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
C39-1 - I5-9 (S)*1
C39-1 - I5-23 (S)*2
|
Always
|
Below 1 Ω
|
C39-1 or I5-9 (S) - Body ground*1
C39-1 or I5-23 (S) - Body ground*2
|
Always
|
10 kΩ or higher
|
-
*1: for TMC Made
-
*2: for TMMC Made
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|