DESCRIPTIONThe combination meter assembly receives the hazard warning signal switch assembly on signal and controls the operation of the hazard warning lights. WIRING DIAGRAMCAUTION / NOTICE / HINTNOTICE: When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored. PROCEDURE
(a) Connect the Techstream to the DLC3. (b) Turn the engine switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Body Electrical / Combination Meter / Data List. (e) Read the Data List according to the display on the Techstream. Body Electrical > Combination Meter > Data List
Body Electrical > Combination Meter > Data List
OK: Normal conditions listed above are displayed.
(a) Remove the hazard warning signal switch assembly. (b) Inspect the hazard warning signal switch assembly.
(a) Disconnect the I5 combination meter assembly connector. (b) Measure the resistance according to the value(s) in the table below. Standard Resistance:
|