Title: G16E-GTS (ENGINE CONTROL): SFI SYSTEM: P148D7E; Purge One Way Valve Stuck Open; 2023 - 2025 MY GR Corolla [09/2022 - ] |
DTC
|
P148D7E
|
Purge One Way Valve Stuck Open
|
DTC SUMMARY
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Note
|
P148D7E
|
Purge One Way Valve Stuck Open
|
No. 1 check valve opened malfunction during key-off EVAP monitor
|
-
No. 1 check valve
-
Leakage from EVAP line (No. 1 check valve - purge VSV)
|
Comes on
|
SAE Code: P148D
|
DTC No.
|
Monitoring Item
|
Detection Timing
|
Detection Logic
|
SAE Code
|
P148D7E
|
No. 1 check valve stuck open
|
EVAP monitoring
(Ignition switch off)
|
2 trip
|
P148D
|
DESCRIPTION
The description can be found in EVAP (Evaporative Emission) System.
Click here
MONITOR DESCRIPTION
5 hours*1 after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.
HINT:
*: If the engine coolant temperature is not less than 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not less than 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.
Sequence
|
Operation
|
Description
|
Duration
|
-
|
ECM activation
|
Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off.
|
-
|
A
|
Atmospheric pressure measurement
|
Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 to 110 kPa(abs) [10.15 to 15.95 psi(abs)], ECM cancels EVAP system monitor.
|
60 seconds
|
B
|
First reference pressure measurement
|
In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
|
360 seconds
|
C
|
EVAP system pressure measurement
|
Vent valve is turned on (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured.
Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
|
15 minutes*
|
D
|
No. 1 check valve monitor
|
Purge VSV is opened and then EVAP system pressure is measured by ECM.
If the pressure does not change, ECM interprets this as normal.
|
20 seconds
|
E
|
Vent valve monitor
|
Vent valve is turned on (opened) and then EVAP system pressure is measured by ECM.
Large increase indicates normal.
|
10 seconds
|
F
|
Second reference pressure measurement
|
After second reference pressure measurement, leak check is performed by comparing first and second reference pressure measurements.
If stabilized system pressure is higher than second reference pressure, ECM determines that EVAP system is leaking.
|
60 seconds
|
-
|
Final check
|
Atmospheric pressure is measured and then monitoring result is recorded by ECM.
|
-
|
*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.
*1
|
Purge VSV: Off (Closed)
|
*2
|
Purge VSV: On (Open)
|
*3
|
Vent Valve: Off (Vent)
|
*4
|
Vent Valve: On (Closed)
|
*5
|
Leak Detection Pump: Off
|
*6
|
Leak Detection Pump: On
|
*7
|
Reference Orifice (0.02 inch)
|
*8
|
Canister Pressure Sensor
|
*9
|
Canister
|
*10
|
Fuel Tank
|
*11
|
Canister Pump Module
|
*12
|
Canister Filter
|
*13
|
No. 1 Check Valve
|
-
|
-
|
*a
|
Operation A:
Atmospheric Pressure Measurement
|
*b
|
Operation B, F:
Reference Pressure Measurement
|
*c
|
Operation C:
EVAP System Pressure Measurement
|
*d
|
Operation D:
No. 1 Check Valve Monitor
|
*e
|
Operation E:
Vent Valve Monitor
|
*f
|
Atmospheric Pressure
|
*g
|
Negative Pressure
|
-
|
-
|
P148D7E: No. 1 check valve stuck open
In operation D, the purge VSV opened and the EVAP system pressure is then measured by the ECM using the canister pressure sensor to conduct an EVAP leak check. If the pressure increases when the purge VSV is open, the ECM interprets this as the No. 1 check valve being stuck open. The ECM illuminates the MIL and stores the DTC.
MONITOR STRATEGY
Required Sensors/Components (Main)
|
No. 1 check valve
Purge VSV
Canister pump module
|
Required Sensors/Components (Related)
|
-
|
Frequency of Operation
|
Once per driving cycle
|
Duration
|
Within 20 minutes
|
MIL Operation
|
2 driving cycles
|
Sequence of Operation
|
None
|
TYPICAL ENABLING CONDITIONS
Monitor runs whenever the following DTCs are not stored
|
None
|
Atmospheric pressure
|
70 kPa(abs) [10.15 psi(abs)] or higher, and less than 110 kPa(abs) [15.95 psi(abs)]
|
Battery voltage
|
10.5 V or higher
|
Vehicle speed
|
Less than 4 km/h (2.5 mph)
|
Ignition switch
|
Off
|
Time after key-off
|
5, 7 or 9.5 hours
|
Canister pressure sensor malfunction (P0452, P0453)
|
Not detected
|
Purge VSV
|
Not operated by scan tool
|
Vent valve
|
Not operated by scan tool
|
Leak detection pump
|
Not operated by scan tool
|
Both of following conditions met before-key off
|
Conditions 1 and 2
|
1. Duration that vehicle is driven
|
5 minutes or more
|
2. EVAP purge operation
|
Performed
|
Engine coolant temperature
|
4.4°C (40°F) or higher, and less than 35°C (95°F)
|
Intake air temperature (for mass air flow meter sub-assembly)
|
4.4°C (40°F) or higher, and less than 35°C (95°F)
|
TYPICAL MALFUNCTION THRESHOLDS
EVAP pressure change after purge VSV on
|
higher than 0.792 kPa(gauge) [0.115 psi(gauge)]
|
MONITOR RESULT
Refer to EVAP system.
Click here
CONFIRMATION DRIVING PATTERN
NOTICE:
-
The Evaporative System Check (Automatic Mode) consists of 7 steps performed automatically by the GTS. It takes a maximum of approximately 24 minutes.
-
Do not perform the Evaporative System Check when the fuel tank is higher than 70% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.
-
Do not run the engine during this operation.
-
When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature less than 35°C (95°F).
HINT:
-
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
-
Connect the GTS to the DLC3.
-
Turn the ignition switch to ON and turn the GTS on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the ignition switch off and wait for at least 30 seconds.
-
Turn the ignition switch to ON and turn the GTS on [A].
-
Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Automatic Mode [B].
-
After the Evaporative System Check is completed, check for All Readiness by entering the following menus: Powertrain / Engine / Utility / All Readiness.
-
Input the DTC: P148D7E.
-
Check the DTC judgment result.
GTS Display
|
Description
|
NORMAL
|
-
DTC judgment completed
-
System normal
|
ABNORMAL
|
-
DTC judgment completed
-
System abnormal
|
INCOMPLETE
|
-
DTC judgment not completed
-
Perform driving pattern after confirming DTC enabling conditions
|
PROCEDURE
Click here
NEXT |
|