P056014
|
System Voltage (BATT) Circuit Short to Ground or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P060629
|
Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid
|
Comes on
|
Master Warning:
Comes on
|
|
P060687
|
Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
|
Comes on
|
Master Warning:
Comes on
|
|
P060A47
|
Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
|
Comes on
|
Master Warning:
Comes on
|
|
P060A87
|
Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message
|
Comes on
|
Master Warning:
Comes on
|
|
P060B16
|
Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold
|
Comes on
|
Master Warning:
Comes on
|
|
P060B49
|
Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
|
Comes on
|
Master Warning:
Comes on
|
|
P062F44
|
Hybrid/EV Battery Energy Control Module EEPROM Data Memory Failure
|
Comes on
|
Master Warning:
Does not come on
|
|
P062F46
|
Hybrid/EV Battery Energy Control Module EEPROM Calibration / Parameter Memory Failure
|
Comes on
|
Master Warning:
Comes on
|
|
P0A1D94
|
Hybrid/EV Powertrain Control Module Unexpected Operation
|
Comes on
|
Master Warning:
Comes on
|
|
P0A8100
|
Hybrid/EV Battery Cooling Fan 1 Control Circuit High
|
Comes on
|
Master Warning:
Comes on
|
|
P0A8111
|
Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground
|
Comes on
|
Master Warning:
Comes on
|
|
P0A8115
|
Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P0A814B
|
Hybrid/EV Battery Cooling Fan 1 Over Temperature
|
Comes on
|
Master Warning:
Comes on
|
|
P0A8196
|
Hybrid/EV Battery Cooling Fan 1 Component Internal Failure
|
Comes on
|
Master Warning:
Comes on
|
|
P0A8198
|
Hybrid/EV Battery Cooling Fan 1 Component or System Over Temperature
|
Comes on
|
Master Warning:
Comes on
|
|
P0A9563
|
High Voltage Fuse Accumulated Load History
|
Does not come on
|
Master Warning:
Does not come on
|
|
P0A9B11
|
Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Ground
|
Comes on
|
Master Warning:
Comes on
|
|
P0A9B15
|
Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P0A9B1C
|
Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0A9B2A
|
Hybrid/EV Battery Temperature Sensor "A" Signal Stuck In Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0AAC11
|
Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground
|
Does not come on
|
Master Warning:
Comes on
|
|
P0AAC15
|
Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open
|
Does not come on
|
Master Warning:
Comes on
|
|
P0ABF11
|
Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground
|
Comes on
|
Master Warning:
Comes on
|
|
P0ABF15
|
Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P0ABF28
|
Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure
|
Comes on
|
Master Warning:
Comes on
|
|
P0ABF2A
|
Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0AC511
|
Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Ground
|
Comes on
|
Master Warning:
Comes on
|
|
P0AC515
|
Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P0AC51C
|
Hybrid/EV Battery Temperature Sensor "B" Voltage Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0AC52A
|
Hybrid/EV Battery Temperature Sensor "B" Signal Stuck In Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0ACA11
|
Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Ground
|
Comes on
|
Master Warning:
Comes on
|
|
P0ACA15
|
Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P0ACA1C
|
Hybrid/EV Battery Temperature Sensor "C" Voltage Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0ACA2A
|
Hybrid/EV Battery Temperature Sensor "C" Signal Stuck In Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0AE811
|
Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Ground
|
Comes on
|
Master Warning:
Comes on
|
|
P0AE815
|
Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Auxiliary Battery or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P0AE81C
|
Hybrid/EV Battery Temperature Sensor "D" Voltage Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0AE82A
|
Hybrid/EV Battery Temperature Sensor "D" Signal Stuck In Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0B0E11
|
Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground
|
Comes on
|
Master Warning:
Comes on
|
|
P0B0E15
|
Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P0B1362
|
Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure
|
Comes on
|
Master Warning:
Comes on
|
|
P0BC211
|
Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Ground
|
Comes on
|
Master Warning:
Comes on
|
|
P0BC215
|
Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Auxiliary Battery or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P0BC21C
|
Hybrid/EV Battery Temperature Sensor "E" Voltage Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0BC22A
|
Hybrid/EV Battery Temperature Sensor "E" Signal Stuck In Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0C3000
|
Hybrid/EV Battery State of Charge High
|
Does not come on
|
Master Warning:
Comes on
|
|
P0C3311
|
Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Ground
|
Comes on
|
Master Warning:
Comes on
|
|
P0C3315
|
Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Auxiliary Battery or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P0C331C
|
Hybrid/EV Battery Temperature Sensor "F" Voltage Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0C332A
|
Hybrid/EV Battery Temperature Sensor "F" Signal Stuck In Range
|
Comes on
|
Master Warning:
Comes on
|
|
P0E2D00
|
Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance
|
Comes on
|
Master Warning:
Comes on
|
|
P1A001C
|
Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P1A6017
|
Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold
|
Comes on
|
Master Warning:
Comes on
|
|
P1A6116
|
Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold
|
Comes on
|
Master Warning:
Comes on
|
|
P1A8000
|
Hybrid/EV Battery Stack 1 Delta SOC High
|
Comes on
|
Master Warning:
Comes on
|
|
P1A8100
|
Hybrid/EV Battery Stack 1 Delta SOC High (Extreme)
|
Comes on
|
Master Warning:
Comes on
|
|
P1A8500
|
Hybrid/EV Battery Stack 2 Delta SOC High
|
Comes on
|
Master Warning:
Comes on
|
|
P1A8600
|
Hybrid/EV Battery Stack 2 Delta SOC High (Extreme)
|
Comes on
|
Master Warning:
Comes on
|
|
P1AC413
|
Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open
|
Comes on
|
Master Warning Light:
Comes on
|
|
P1AC49E
|
Hybrid/EV Battery Stack 1 Current Interrupt Device Stuck On
|
Comes on
|
Master Warning Light:
Comes on
|
|
P1AC513
|
Hybrid/EV Battery Stack 2 Current Interrupt Device Circuit Open
|
Comes on
|
Master Warning Light:
Comes on
|
|
P1AC59E
|
Hybrid/EV Battery Stack 2 Current Interrupt Device Stuck On
|
Comes on
|
Master Warning Light:
Comes on
|
|
P1AFC00
|
System Voltage (AM) Circuit Voltage Below Threshold
|
Does not come on
|
Master Warning:
Comes on
|
|
P1AFD00
|
Flying Capacitor Circuit Voltage Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P1AFD1C
|
Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P1AFF00
|
Hybrid/EV Battery ECU Multiple Reset
|
Does not come on
|
Master Warning:
Comes on
|
|
P1C8549
|
High Voltage Power Resource Internal Electronic Failure
|
Does not come on
|
Master Warning:
Comes on
|
|
P1C9F11
|
Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Ground
|
Comes on
|
Master Warning:
Comes on
|
|
P1C9F15
|
Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Auxiliary Battery or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P1C9F1C
|
Hybrid/EV Battery Current Sensor for Driving Control Voltage Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P1CBB12
|
Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery
|
Comes on
|
Master Warning:
Comes on
|
|
P1CBB14
|
Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open
|
Comes on
|
Master Warning:
Comes on
|
|
P1CC81E
|
Hybrid/EV Battery Stack 1 Voltage Difference Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P1CC91E
|
Hybrid/EV Battery Stack 2 Voltage Difference Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P300000
|
Hybrid/EV Battery Discharge Control Malfunction
|
Does not come on
|
Master Warning:
Does not come on
|
|
P300016
|
Hybrid/EV Battery Control System Circuit Voltage Below Threshold
|
Does not come on
|
Master Warning:
Comes on
|
|
P30004B
|
Hybrid/EV Battery Control System Over Temperature
|
Does not come on
|
Master Warning:
Comes on
|
|
P301A1C
|
Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P306562
|
Hybrid/EV Battery Temperature Sensor "Group 1" Signal Compare Failure
|
Comes on
|
Master Warning:
Comes on
|
|
P306A62
|
Hybrid/EV Battery Temperature Sensor "Group 2" Signal Compare Failure
|
Comes on
|
Master Warning:
Comes on
|
|
P31AA17
|
Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold
|
Comes on
|
Master Warning:
Comes on
|
|
P31AB16
|
Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold
|
Comes on
|
Master Warning:
Comes on
|
|
P31B300
|
Hybrid/EV Battery Voltage High
|
Comes on
|
Master Warning:
Comes on
|
|
P31B400
|
Extreme Hybrid/EV Battery Charging Current
|
Does not come on
|
Master Warning:
Comes on
|
|
P31B549
|
Hybrid/EV Battery Internal Electronic Failure
|
Does not come on
|
Master Warning:
Comes on
|
|
P33DA1E
|
Hybrid/EV Battery Stack 1 Circuit Resistance Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P33DB1E
|
Hybrid/EV Battery Stack 2 Circuit Resistance Out of Range
|
Comes on
|
Master Warning:
Comes on
|
|
P33E01B
|
Hybrid/EV Battery Stack 1 Circuit Resistance Above Threshold
|
Comes on
|
Master Warning:
Comes on
|
|
P33E11B
|
Hybrid/EV Battery Stack 2 Circuit Resistance Above Threshold
|
Comes on
|
Master Warning:
Comes on
|
|
P33EC16
|
(Extreme) Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold
|
Comes on
|
Master Warning:
Comes on
|
|
P33ED16
|
(Extreme) Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold
|
Comes on
|
Master Warning:
Comes on
|
|
U010087
|
Lost Communication with ECM/PCM "A" Missing Message
|
Comes on
|
Master Warning:
Comes on
|
|
U029387
|
Lost Communication with Hybrid/EV Powertrain Control Module Missing Message
|
Comes on
|
Master Warning:
Comes on
|
|
U115087
|
Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message
|
Comes on
|
Master Warning:
Comes on
|
|