Last Modified: 05-13-2024 6.11:8.1.0 Doc ID: RM100000001N350
Model Year Start: 2021 Model: Corolla Prod Date Range: [04/2020 - 09/2022]
Title: HYBRID / BATTERY CONTROL: HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY with P610): P1AFD00; Flying Capacitor Circuit Voltage Out of Range; 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022]

DTC

P1AFD00

Flying Capacitor Circuit Voltage Out of Range

DESCRIPTION

The battery ECU assembly monitors its internal operation and will store these DTCs when it detects an internal malfunction.

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Warning Indicate

P1AFD00

Flying Capacitor Circuit Voltage Out of Range

ECU internal malfunction

(1 trip detection logic)

  • Battery ECU assembly
  • No. 1 HV supply stack sub-assembly
  • No. 2 HV supply stack sub-assembly

Comes on

Master Warning:

Comes on

MONITOR DESCRIPTION

The battery ECU assembly monitors its internal operation. If the internal operation is malfunctioning, the battery ECU assembly illuminates the MIL and stores a DTC.

MONITOR STRATEGY

Related DTCs

P1AFD (INF P1AFD00): Battery stack voltage sense circuit

Required sensors/components

Battery ECU assembly

Frequency of operation

Continuous

Duration

TMC's intellectual property

MIL operation

Immediately

Sequence of operation

None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not stored

TMC's intellectual property

Other conditions belong to TMC's intellectual property

-

TYPICAL MALFUNCTION THRESHOLDS

TMC's intellectual property

-

COMPONENT OPERATING RANGE

Battery ECU assembly

DTC P1AFD (INF P1AFD00) is not detected

CONFIRMATION DRIVING PATTERN

HINT:

  • After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

    Click here 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022]; HYBRID / BATTERY CONTROL: HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY with P610): UTILITY

  • When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.

    Click here 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022]; HYBRID / BATTERY CONTROL: HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY with P610): DTC CHECK / CLEAR

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 2 minutes or more.
  5. Turn the power switch on (IG) and turn the Techstream on.
  6. With power switch on (IG) and wait for 30 seconds or more.[*1]

    HINT:

    [*1]: Normal judgment procedure.

    The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.

  7. Enter the following menus: Powertrain / HV Battery / Utility / All Readiness.
  8. Check the DTC judgment result.

    HINT:

    • If the judgment result shows NORMAL, the system is normal.
    • If the judgment result shows ABNORMAL, the system has a malfunction.
    • If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.

CAUTION / NOTICE / HINT

CAUTION:

  • Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
    • Inspecting the high-voltage system
    • Disconnecting the low voltage connector of the inverter with converter assembly
    • Disconnecting the low voltage connector of the HV battery
  • To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
  • After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    *a

    Without waiting for 10 minutes

    Click here 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022]; HYBRID / BATTERY CONTROL: HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY with P610): PRECAUTION

    HINT:

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

  • Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.

    If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.

  • When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

    *a

    Dealer

    *b

    Battery Collection Agent

    • Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.
  • Before returning the HV battery, make sure to perform a recovery inspection.

    Click here 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022]; HYBRID / BATTERY CONTROL: HV BATTERY (for LITHIUM-ION BATTERY): RECOVERY INSPECTION

  • Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection.

    Click here 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022]; HYBRID / BATTERY CONTROL: HV BATTERY STACK (for LITHIUM-ION BATTERY): RECOVERY INSPECTION

  • Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery and HV supply stack sub-assemblies.
  • After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click here 2021 - 2022 MY Corolla Corolla Hatchback Corolla HV GR Corolla [04/2020 - 09/2022]; INTRODUCTION: REPAIR INSTRUCTION: INITIALIZATION

PROCEDURE

1.

CHECK DTC OUTPUT (HV BATTERY)

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Enter the following menus: Powertrain / HV Battery / Trouble Codes.

(d) Check for DTCs.

Powertrain > HV Battery > Trouble Codes

Result

Proceed to

"P1AFD00" only is output.

A

DTCs except "P1AFD00" are output.

B

(e) Turn the power switch off.

B

GO TO DTC CHART (HYBRID BATTERY SYSTEM)

A

2.

CHECK CONNECTOR CONNECTION CONDITION (HV BATTERY HIGH VOLTAGE CONNECTOR)

CAUTION:

Be sure to wear insulated gloves and protective goggles.

(a) Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

(b) Remove the No. 1 HV battery hose.

Click here 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022]; HYBRID / BATTERY CONTROL: BATTERY ECU (for LITHIUM-ION BATTERY): REMOVAL+

(c) Check the connector connections and contact pressure of the relevant terminals for the HV supply stack sub-assembly.

Click here 2019 - 2025 MY Corolla Corolla Hatchback Corolla HV GR Corolla [06/2018 -        ]; INTRODUCTION: HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS: ELECTRONIC CIRCUIT INSPECTION PROCEDURE

OK:

The connector is connected securely and there are no contact problems.

Result:

Result

Proceed to

OK

A

Not connected securely

The terminals are not damaged or corroded

B

Not connected securely

The terminals are damaged or corroded

(No. 1 HV supply stack sub-assembly side)

C

Not connected securely

The terminals are damaged or corroded

(No. 2 HV supply stack sub-assembly side)

D

(d) Install the No. 1 HV battery hose.

A

REPLACE BATTERY ECU ASSEMBLY

B

CONNECT SECURELY

C

REPLACE NO. 1 HV SUPPLY STACK SUB-ASSEMBLY

D

REPLACE NO. 2 HV SUPPLY STACK SUB-ASSEMBLY