Last Modified: 07-31-2024 6.11:8.1.0 Doc ID: RM100000001N32U
Model Year Start: 2021 Model: Corolla Prod Date Range: [04/2020 - 09/2022]
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY with P610): P062F46; Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure; 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022]

DTC

P062F46

Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure

DESCRIPTION

The inverter with converter assembly monitors its internal operation and will store this DTC if it detects a malfunction of its EEPROM.

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Warning Indicate

P062F46

Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure

ECU internal malfunction

(EEPROM error)

(1 trip detection logic)

Inverter with converter assembly

Comes on

Master Warning:

Comes on

MONITOR DESCRIPTION

The motor generator control ECU monitors its internal operation. If the internal operation is malfunctioning, the motor generator control ECU illuminates the MIL and stores a DTC.

MONITOR STRATEGY

Related DTCs

P062F (INF P062F46): Parameter memory failure

Required sensors/components

Motor generator control ECU

Frequency of operation

Continuous

Duration

TMC's intellectual property

MIL operation

1 driving cycle

Sequence of operation

None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not stored

TMC's intellectual property

Other conditions belong to TMC's intellectual property

-

TYPICAL MALFUNCTION THRESHOLDS

TMC's intellectual property

-

COMPONENT OPERATING RANGE

Motor generator control ECU

DTC P062F (INF P062F46) is not detected

CONFIRMATION DRIVING PATTERN

HINT:

  • After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

    Click here 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022]; HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY with P610): UTILITY

  • When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.

    Click here 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022]; HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY with P610): DTC CHECK / CLEAR

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 2 minutes or more.
  5. Turn the power switch on (IG) and turn the Techstream on.
  6. With power switch on (IG) and wait for 15 seconds or more. [*1]

    HINT:

    [*1]: Normal judgment procedure.

    The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.

  7. Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
  8. Check the DTC judgment result.

    HINT:

    • If the judgment result shows NORMAL, the system is normal.
    • If the judgment result shows ABNORMAL, the system has a malfunction.
    • If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.

CAUTION / NOTICE / HINT

NOTICE:

Be sure to check that the applicable DTC is output from the motor generator control system.

PROCEDURE

1.

CHECK DTC OUTPUT (HEALTH CHECK)

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Enter the following menus: System Select / Health Check.

(d) Check for DTCs.

Result

Proceed to

P062F46 is output from the motor generator control system.

A

P062F46 is output from any system other than the motor generator control system.

B

(e) Turn the power switch off.

A

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

B

GO TO PERFORM DIAGNOSIS FOR RESPECTIVE SYSTEM