Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM100000001N32S |
Model Year Start: 2021 |
Model: Corolla |
Prod Date Range: [04/2020 - 09/2022] |
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY with P610): P034000,P034031; Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor; 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022] |
DTC
|
P034000
|
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor
|
DTC
|
P034031
|
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal
|
DESCRIPTION
If the cam position signal pulse sent from the ECM via a direct line is abnormal, the motor generator control ECU (MG ECU) (built into the inverter with converter assembly) stores DTC P034000 or P034031.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P034000
|
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor
|
GI signal (camshaft position sensor) is not input for 2 sec. or more while the engine is running*
(1 trip detection logic)
|
-
SFI system
-
Inverter with converter assembly
-
ECM
-
Wire harness or connector
|
Does not come on
|
Master Warning:
Comes on
|
P034031
|
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal
|
GI signal (camshaft position sensor) is not input for 2 sec. or more while the engine is running*
(1 trip detection logic)
|
-
SFI system
-
Inverter with converter assembly
-
ECM
-
Wire harness or connector
|
Does not come on
|
Master Warning:
Comes on
|
HINT:
*: When this DTC is stored, vibration may occur when the engine is stopped.
Related Data List
DTC No.
|
Data List
|
P034000
P034031
|
-
Crank Position (Hybrid control system)
-
Engine Speed
|
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Turn the power switch on (READY).
-
With the vehicle stopped, move the shift lever to P.
-
Depress the accelerator pedal to start the engine.
-
Depress the accelerator pedal and maintain the engine speed at 1000 rpm or more for 5 seconds or more.
NOTICE:
As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with power switch on (READY) after repairs have been performed.
-
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
PROCEDURE
1.
|
CHECK DTC OUTPUT (ENGINE)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Engine / Trouble Codes.
(d) Check for DTCs.
Powertrain > Engine > Trouble Codes
Result
|
Proceed to
|
SFI system DTCs are not output.
|
A
|
Any of the following DTCs are also output.
|
B
|
Relevant Diagnosis
|
P034011
|
Camshaft Position Sensor "A" Bank 1 or Single Sensor Circuit Short to Ground
|
P034015
|
Camshaft Position Sensor "A" Bank 1 or Single Sensor Circuit Short to Battery or Open
|
P03402A
|
Camshaft Position Sensor "A" Bank 1 or Single Sensor Signal Stuck in Range
|
P034031
|
Camshaft Position Sensor "A" Bank 1 or Single Sensor No Signal
|
(e) Turn the power switch off.
A
|
|
|
2.
|
CHECK DTC OUTPUT (MOTOR GENERATOR CONTROL)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Motor Generator > Trouble Codes
Result
|
Proceed to
|
None of the following DTCs are output.
|
A
|
Any of the following DTCs are also output.
|
B
|
DTC No.
|
Relevant Diagnosis
|
P06B01C
|
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
P06D61C
|
Generator Control Module Offset Power Circuit Voltage Out of Range
|
P0A1B1F
|
Generator Control Module Circuit Intermittent
|
P1C2B49
|
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
|
P1C2B1C
|
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
|
P1CAD49
|
Drive Motor "A" Position Sensor Internal Electronic Failure
|
P1CB038
|
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
|
P313487
|
Communication Error from Drive Motor "A" to Generator Missing Message
|
P313483
|
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect
|
P313486
|
Communication Error from Drive Motor "A" to Generator Signal Invalid
|
HINT:
P034000 or P034031 may be stored due to a malfunction which also causes the DTCs in the preceding table to be stored. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
(e) Turn the power switch off.
A
|
|
|
3.
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
|
Click here
Result
|
Proceed to
|
OK
|
A
|
NG (The connector is not connected securely.)
|
B
|
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.)
|
C
|
B |
|
CONNECT SECURELY
|
C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
A
|
|
|
4.
|
CHECK CONNECTOR CONNECTION CONDITION (ECM CONNECTOR)
|
Click here
NG |
|
CONNECT SECURELY
|
OK
|
|
|
5.
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ECM)
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the C89 inverter with converter assembly connector.
(c) Disconnect the C77 ECM connector.
(d) Connect the cable to the negative (-) auxiliary battery terminal.
(e) Turn the power switch on (IG).
(f) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
C89-10 (GI) - Body ground
|
Power switch on (IG)
|
Below 1 V
|
NOTICE:
Turning the power switch on (IG) with the inverter with converter assembly connector and ECM connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
|
|
*a
|
Front view of wire harness connector
(to Inverter with Converter Assembly)
|
*b
|
Front view of wire harness connector
(to ECM)
|
|
|
(g) Turn the power switch off.
(h) Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
Tester Connection
|
Condition
|
Specified Condition
|
C89-10 (GI) - C77-70 (G2O)
|
Power switch off
|
Below 1 Ω
|
Standard Resistance (Check for Short):
Tester Connection
|
Condition
|
Specified Condition
|
C89-10 (GI) or C77-70 (G2O) - Body ground and other terminals
|
Power switch off
|
10 kΩ or higher
|
(i) Disconnect the cable from the negative (-) auxiliary battery terminal.
(j) Reconnect the C77 ECM connector.
(k) Reconnect the C89 inverter with converter assembly connector.
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
(a) Disconnect the C77 and A46 ECM connectors.
(b) Measure the resistance according to the value(s) in the table below.
*a
|
Component without harness connected
(ECM)
|
-
|
-
|
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
C77-70 (G2O) - C77-59 (E1)
|
Power switch off
|
10 kΩ or higher
|
(c) Reconnect the C77 and A46 ECM connectors.
|