Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM100000001HTL9 |
Model Year Start: 2020 |
Model: Corolla Hatchback |
Prod Date Range: [03/2019 - 03/2023] |
Title: M20A-FKS (ENGINE CONTROL): SFI SYSTEM: P052014; Engine Oil Pressure Sensor/Switch "A" Circuit Short to Ground or Open; 2020 - 2023 MY Corolla Corolla Hatchback [03/2019 - 03/2023] |
DTC
|
P052014
|
Engine Oil Pressure Sensor/Switch "A" Circuit Short to Ground or Open
|
DESCRIPTION
Refer to DTC P052012.
Click here
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Memory
|
Note
|
P052014
|
Engine Oil Pressure Sensor/Switch "A" Circuit Short to Ground or Open
|
Diagnosis condition:
Abnormal condition:
-
The oil pressure sensor output voltage is less than 0.159 V.
Malfunction time:
Trip logic:
Detection conditions:
Sensors/components used for detection:
|
-
Open or short in oil pressure sensor circuit
-
Oil pressure and temperature sensor (oil pressure sensor)
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P0522
-
DTC for Mexico Models: Applies
|
Related Data List
DTC No.
|
Data List
|
P052014
|
Engine Oil Pressure
|
MONITOR DESCRIPTION
When the ignition switch is turned ON and the output voltage of the oil pressure sensor is less than 0.159 V for 5 seconds or more, the ECM determines that the oil pressure sensor circuit is malfunctioning and illuminates the MIL and stores a DTC.
MONITOR STRATEGY
Related DTCs
|
P0522: Engine oil pressure sensor range check (low voltage)
|
Required Sensors/Components (Main)
|
Oil pressure sensor
|
Required Sensors/Components (Related)
|
-
|
Frequency of Operation
|
Continuous
|
Duration
|
5 seconds
|
MIL Operation
|
Immediate
|
Sequence of Operation
|
None
|
TYPICAL ENABLING CONDITIONS
Monitor runs whenever the following DTCs are not stored
|
None
|
All of the following conditions are met
|
-
|
Battery voltage
|
8 V or higher
|
Ignition switch
|
ON
|
Starter
|
Off
|
TYPICAL MALFUNCTION THRESHOLDS
Engine oil pressure sensor voltage
|
Less than 0.159 V
|
CONFIRMATION DRIVING PATTERN
Refer to DTC P052012.
Click here
WIRING DIAGRAM
Refer to DTC P052012.
Click here
CAUTION / NOTICE / HINT
HINT:
Read Freeze Frame Data using the Techstream. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
PROCEDURE
1.
|
CHECK TERMINAL VOLTAGE (OIL PRESSURE SENSOR)
|
*a
|
Front view of wire harness connector
(to Oil Pressure Sensor)
|
HINT:
Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.
(a) Disconnect the oil pressure sensor connector.
(b) Turn the ignition switch to ON.
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
C41-3 (VC) - Body ground
|
Ignition switch ON
|
4.5 to 5.5 V
|
OK
|
|
|
2.
|
CHECK INTERNAL RESISTANCE (ECM)
|
(a) Turn the ignition switch off.
(b) Disconnect the oil pressure sensor connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
C41-1 (POUT) - C41-2 (GND)
|
Ignition switch off
|
190 to 210 kΩ
|
HINT:
As voltage is still supplied to the ECM after the ignition switch is turned off, this check cannot be performed correctly during the shut-down process.
Result
|
Proceed to
|
190 to 210 kΩ
|
A
|
Below 190 kΩ
|
B
|
Higher than 210 kΩ
|
C
|
B
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (OIL PRESSURE SENSOR - ECM)
|
(a) Disconnect the oil pressure sensor connector.
(b) Disconnect the ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
C41-1 (POUT) - C41-2 (GND) or C76-122 (PEO) - C76-100 (EPEO)
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
4.
|
CHECK HARNESS AND CONNECTOR (OIL PRESSURE SENSOR - ECM)
|
(a) Disconnect the oil pressure sensor connector.
(b) Disconnect the ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
C41-1 (POUT) - C76-122 (PEO)
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
5.
|
CHECK HARNESS AND CONNECTOR (OIL PRESSURE SENSOR - ECM)
|
(a) Disconnect the oil pressure sensor connector.
(b) Disconnect the ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
C41-3 (VC) - C76-99 (VCPE)
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|