Title: M20A-FKS (ENGINE CONTROL): SFI SYSTEM: P011011; Intake Air Temperature Sensor 1 Bank 1 Circuit Short to Ground; 2020 - 2023 MY Corolla Corolla Hatchback [03/2019 - 03/2023] |
DTC
|
P011011
|
Intake Air Temperature Sensor 1 Bank 1 Circuit Short to Ground
|
DESCRIPTION
The intake air temperature sensor, mounted on the mass air flow meter sub-assembly, monitors the intake air temperature. The intake air temperature sensor is a built-in thermistor with a resistance that varies according to the temperature of the intake air. When the intake air temperature is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the ECM as voltage changes (see Fig. 1).
The intake air temperature sensor is powered by a 5 V supply from the THA terminal of the ECM, via resistor R.
Resistor R and the intake air temperature sensor are connected in series. When the resistance value of the intake air temperature sensor changes, according to changes in the intake air temperature, the voltage at terminal THA also varies. Based on this signal, the ECM performs various checks and compensations related to intake air temperature in the engine management system.
HINT:
When DTC P011011 is stored, the ECM enters fail-safe mode. During fail-safe mode, the intake air temperature is estimated to be 20°C (68°F) by the ECM. Fail-safe mode continues until a pass condition is detected, and the ignition switch is then turned off.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Memory
|
Note
|
P011011
|
Intake Air Temperature Sensor 1 Bank 1 Circuit Short to Ground
|
Diagnosis condition:
Abnormal condition:
-
The intake air temperature sensor output voltage is less than 0.176 V*1 or 0.142 V*2.
Malfunction time:
Trip logic:
Detection conditions:
Sensors/components used for detection:
-
Intake air temperature sensor
|
-
Short in intake air temperature sensor circuit
-
Mass air flow meter sub-assembly (intake air temperature sensor)
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P0112
-
DTC for Mexico Models: Applies
|
-
*1: except Mexico Models
*2: for Mexico Models
HINT:
When this DTC is output, check the intake air temperature in the Data List. Enter the following menus: Powertrain / Engine / Data List / Intake Air Temperature.
except Mexico Models
DTC No.
|
Intake Air Temperature
|
Malfunction
|
P011011
|
Higher than 128°C (262°F)
|
Short to ground in THA circuit
|
for Mexico Models
DTC No.
|
Intake Air Temperature
|
Malfunction
|
P011011
|
Higher than 138°C (280°F)
|
Short to ground in THA circuit
|
If the Data List values is normal it may be due to a temporary recovery from the malfunction condition. Check for intermittent problems.
Click here
MONITOR DESCRIPTION
When the ignition switch is turned ON and the output voltage of the intake air temperature sensor is less than 0.176 V*1 or 0.142 V*2 for 0.5 seconds or more, the ECM determines that the intake air temperature sensor circuit is malfunctioning and illuminates the MIL and stores a DTC.
-
*1: except Mexico Models
*2: for Mexico Models
MONITOR STRATEGY
Related DTCs
|
P0112: Intake air temperature sensor range check (low voltage)
|
Required Sensors/Components (Main)
|
Intake air temperature sensor
|
Required Sensors/Components (Related)
|
-
|
Frequency of Operation
|
Continuous
|
Duration
|
0.5 seconds
|
MIL Operation
|
Immediate
|
Sequence of Operation
|
None
|
TYPICAL ENABLING CONDITIONS
Monitor runs whenever the following DTCs are not stored
|
None
|
All of the following conditions are met
|
-
|
Battery voltage
|
8 V or higher
|
Ignition switch
|
ON
|
Starter
|
Off
|
TYPICAL MALFUNCTION THRESHOLDS
Intake air temperature sensor voltage [Intake air temperature]
|
Less than 0.176 V [Higher than 128°C (262°F)]: except Mexico Models
Less than 0.142 V [Higher than 138°C (280°F)]: for Mexico Models
|
CONFIRMATION DRIVING PATTERN
-
Connect the Techstream to the DLC3.
-
Turn the ignition switch to ON.
-
Turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the ignition switch off and wait for at least 30 seconds.
-
Turn the ignition switch to ON [A].
-
Turn the Techstream on.
-
Wait 0.5 seconds or more [B].
-
Enter the following menus: Powertrain / Engine / Trouble Codes [C].
-
Read the pending DTCs.
HINT:
-
If a pending DTC is output, the system is malfunctioning.
-
If a pending DTC is not output, perform the following procedure.
-
Enter the following menus: Powertrain / Engine / Utility / All Readiness.
-
Proceed to the next screen and enter the DTC to be checked.
-
Check the DTC judgment result.
Techstream Display
|
Description
|
NORMAL
|
-
DTC judgment completed
-
System normal
|
ABNORMAL
|
-
DTC judgment completed
-
System abnormal
|
INCOMPLETE
|
-
DTC judgment not completed
-
Perform driving pattern after confirming DTC enabling conditions
|
WIRING DIAGRAM
Refer to DTC P010012.
Click here
CAUTION / NOTICE / HINT
HINT:
Read Freeze Frame Data using the Techstream. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
PROCEDURE
1.
|
READ VALUE USING TECHSTREAM (INTAKE AIR TEMPERATURE)
|
*1
|
Intake Air Temperature Sensor
|
*2
|
ECM
|
(a) Disconnect the intake air temperature sensor connector.
(b) Connect the Techstream to the DLC3.
(c) Turn the ignition switch to ON.
(d) Turn the Techstream on.
(e) Enter the following menus: Powertrain / Engine / Data List / Intake Air Temperature.
Powertrain > Engine > Data List
Tester Display
|
Intake Air Temperature
|
(f) According to the display on the Techstream, read the Data List.
OK:
Techstream Display
|
Specified Condition
|
Intake Air Temperature
|
-40°C (-40°F)
|
HINT:
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
Click here
NG
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (INTAKE AIR TEMPERATURE SENSOR - ECM)
|
(a) Disconnect the intake air temperature sensor connector.
(b) Disconnect the ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
C26-4 (THA) or C76-102 (THA) - Body ground and other terminals
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|