Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM100000001HT6I |
Model Year Start: 2020 |
Model: Corolla |
Prod Date Range: [03/2019 - 11/2022] |
Title: 2ZR-FAE (ENGINE CONTROL): SFI SYSTEM: P2420; Evaporative Emission Pressure Switching Valve Stuck OFF; 2020 - 2023 MY Corolla [03/2019 - 11/2022] |
DTC
|
P2420
|
Evaporative Emission Pressure Switching Valve Stuck OFF
|
DTC SUMMARY
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Memory
|
Note
|
P2420
|
Evaporative Emission Pressure Switching Valve Stuck OFF
|
Following condition met during key-off EVAP monitor:
EVAP pressure change when vent valve closed (on) less than 0.3 kPa [0.044 psi]
|
-
Canister pump module (reference orifice, leak detection pump, vent valve)
-
Connector/wire harness (Canister pump module - ECM)
-
Canister (filter inside canister clogged)
-
ECM
|
Comes on
|
DTC stored
|
DTC for Mexico Models
- Does not apply
|
DTC No.
|
Monitoring Item
|
Detection Timing
|
Detection Logic
|
P2420
|
Vent valve stuck open (vent)
|
While ignition switch off
|
2 trip
|
HINT:
The vent valve is built into the canister pump module.
DESCRIPTION
The description can be found in EVAP (Evaporative Emission) System.
Click here
MONITOR DESCRIPTION
5 hours* after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.
HINT:
*: If the engine coolant temperature is not less than 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not less than 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.
Sequence
|
Operation
|
Description
|
Duration
|
-
|
ECM activation
|
Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch is turned off.
|
-
|
A
|
Atmospheric pressure measurement
|
Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 to 110 kPa(abs) [10.15 to 15.95 psi(abs)], ECM cancels EVAP system monitor.
|
60 seconds
|
B
|
First reference pressure measurement
|
In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
|
360 seconds
|
C
|
EVAP system pressure measurement
|
Vent valve is turned on (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and then EVAP system pressure is measured. Write down measured value as they will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
|
15 minutes*
|
D
|
Purge VSV monitor
|
Purge VSV is opened and then EVAP system pressure is measured by ECM.
Large increase indicates normal.
|
10 seconds
|
E
|
Second reference pressure measurement
|
After second reference pressure measurement, leak check is performed by comparing first and second reference pressure measurements.
If stabilized system pressure is higher than second reference pressure, ECM determines that there is a leak in EVAP system.
|
60 seconds
|
-
|
Final check
|
Atmospheric pressure is measured and then monitoring result is recorded by ECM.
|
-
|
*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.
*1
|
Purge VSV: Off (Closed)
|
*2
|
Purge VSV: On (Open)
|
*3
|
Vent Valve: Off (Vent)
|
*4
|
Vent Valve: On (Closed)
|
*5
|
Leak Detection Pump: Off
|
*6
|
Leak Detection Pump: On
|
*7
|
Reference Orifice (0.02 inch)
|
*8
|
Canister Pressure Sensor
|
*9
|
Canister
|
*10
|
Fuel Tank
|
*11
|
Canister Pump Module
|
*12
|
Canister Filter
|
*a
|
Operation A:
Atmospheric Pressure Measurement
|
*b
|
Operation B, E:
Reference Pressure Measurement
|
*c
|
Operation C:
EVAP System Pressure Measurement
|
*d
|
Operation D:
Purge VSV Monitor
|
*e
|
Atmospheric Pressure
|
*f
|
Negative Pressure
|
P2420: Vent valve stuck open (vent)
In operation C, the vent valve turns on (closed) and the EVAP system pressure is then measured by the ECM using the canister pressure sensor to conduct an EVAP leak check. If the pressure does not increase when the vent valve is open, the ECM interprets this as the vent valve being stuck open. In this case the ECM will illuminate the MIL and store this DTC.
MONITOR STRATEGY
Required Sensors/Components (Main)
|
Purge VSV
Canister pump module
|
Required Sensors/Components (Related)
|
-
|
Frequency of Operation
|
Once per driving cycle
|
Duration
|
Within 7 minutes (varies with amount of fuel in tank)
|
MIL Operation
|
2 driving cycles
|
Sequence of Operation
|
None
|
TYPICAL ENABLING CONDITIONS
Atmospheric pressure
|
70 kPa(abs) [10.15 psi(abs)] or higher, and less than 110 kPa(abs) [15.95 psi(abs)]
|
Battery voltage
|
10.5 V or higher
|
Vehicle speed
|
Less than 4 km/h (2.5 mph)
|
Ignition switch
|
Off
|
Time after key-off
|
5, 7 or 9.5 hours
|
Canister pressure sensor malfunction (P0451, P0452, P0453)
|
Not detected
|
Purge VSV
|
Not operated by scan tool
|
Vent valve
|
Not operated by scan tool
|
Leak detection pump
|
Not operated by scan tool
|
Both of the following conditions met before key-off
|
Conditions 1 and 2
|
1. Duration that vehicle is driven
|
5 minutes or more
|
2. EVAP purge operation
|
Performed
|
Engine coolant temperature
|
4.4°C (40°F) or higher, and less than 35°C (95°F)
|
Intake air temperature
|
4.4°C (40°F) or higher, and less than 35°C (95°F)
|
TYPICAL MALFUNCTION THRESHOLDS
EVAP pressure change after EVAP canister vent valve on
|
Less than 0.3 kPa [0.044 psi]
|
MONITOR RESULT
Refer to EVAP system.
Click here
CONFIRMATION DRIVING PATTERN
-
Connect the Techstream to the DLC3.
-
Turn the ignition switch to ON.
-
Turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the ignition switch off and wait for at least 30 seconds.
-
Turn the ignition switch to ON.
-
Turn the Techstream on.
-
Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.
-
After the Evaporative System Check is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
-
Input the DTC: P2420.
-
Check the DTC judgment result.
Techstream Display
|
Description
|
NORMAL
|
-
DTC judgment completed
-
System normal
|
ABNORMAL
|
-
DTC judgment completed
-
System abnormal
|
INCOMPLETE
|
-
DTC judgment not completed
-
Perform driving pattern after confirming DTC enabling conditions
|
N/A
|
-
Unable to perform DTC judgment
-
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit
|
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs.
Click here
HINT:
-
If a permanent DTC is output, the system is malfunctioning.
-
If no permanent DTC is output, the system is normal.
PROCEDURE
(a) Refer to EVAP System.
Click here
NEXT |
|
END
|
|