Last Modified: 05-13-2024 |
6.11:8.1.0 |
Doc ID: RM100000001HGK8 |
Model Year Start: 2020 |
Model: GR Corolla |
Prod Date Range: [01/2019 - 09/2022] |
Title: THEFT DETERRENT / KEYLESS ENTRY: THEFT DETERRENT SYSTEM (for Gasoline Model): Unlock Warning Switch Circuit; 2020 - 2022 MY Corolla Corolla Hatchback GR Corolla [01/2019 - 09/2022] |
Unlock Warning Switch Circuit
|
DESCRIPTION
The unlock warning switch assembly turns on when the key is inserted into the ignition key cylinder and turns off when the key is removed.
WIRING DIAGRAM
PROCEDURE
1.
|
READ VALUE USING TECHSTREAM (KEY UNLOCK WARNING SW)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Main Body / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Main Body > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Key Unlock Warning SW
|
Unlock warning switch
|
OFF or ON
|
OFF: Ignition key not inserted
ON: Ignition key inserted
|
-
|
Body Electrical > Main Body > Data List
Tester Display
|
Key Unlock Warning SW
|
OK:
The Techstream display changes correctly in response to the unlock warning switch assembly status.
NG
|
|
|
2.
|
INSPECT UNLOCK WARNING SWITCH ASSEMBLY
|
(a) Remove the unlock warning switch assembly.
Click here
(b) Inspect the unlock warning switch assembly.
Click here
OK
|
|
|
3.
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
|
(a) Remove the main body ECU (multiplex network body ECU).
Click here
*a
|
Component without harness connected
(Instrument Panel Junction Block Assembly)
|
-
|
-
|
(b) Disconnect the 4E instrument panel junction block assembly connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
4E-41 - MB-3 (KSW)
|
Always
|
Below 1 Ω
|
OK
|
|
|
4.
|
CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - UNLOCK WARNING SWITCH ASSEMBLY AND BODY GROUND)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
4E-41 - I13-1 (UN+)
|
Always
|
Below 1 Ω
|
4E-41 or I13-1 (UN+) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
I13-2 (UN-) - Body ground
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|