Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM100000001HGK4 |
Model Year Start: 2020 |
Model: GR Corolla |
Prod Date Range: [01/2019 - 09/2022] |
Title: THEFT DETERRENT / KEYLESS ENTRY: THEFT DETERRENT SYSTEM (for Gasoline Model): Security Horn Circuit; 2020 - 2022 MY Corolla Corolla Hatchback GR Corolla [01/2019 - 09/2022] |
DESCRIPTION
When the theft deterrent system is switched from the armed state to the alarm sounding state, the main body ECU (multiplex network body ECU) transmits a signal to cause the security horn assembly to sound at intervals of 0.4 seconds.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
PROCEDURE
1.
|
PERFORM ACTIVE TEST USING TECHSTREAM (SECURITY HORN)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Main Body / Active Test.
(e) Perform the Active Test according to the display on the Techstream.
Body Electrical > Main Body > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
Security Horn
|
Security horn Assembly
|
OFF/ON
|
-
|
Body Electrical > Main Body > Active Test
Tester Display
|
Security Horn
|
OK:
The security horn assembly sounds and stops correctly when operated through the Techstream.
NG
|
|
|
2.
|
INSPECT SECURITY HORN ASSEMBLY
|
(a) Remove the security horn assembly.
Click here
(b) Inspect the security horn assembly.
Click here
OK
|
|
|
(a) Remove the S-HORN relay from the No. 3 relay block assembly.
|
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
3 - 5
|
Battery voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
3 - 5
|
Battery voltage applied between terminals 1 and 2
|
Below 1 Ω
|
NG |
|
REPLACE S-HORN RELAY
|
OK
|
|
|
4.
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
|
(a) Remove the main body ECU (multiplex network body ECU).
Click here
*a
|
Component without harness connected
(Instrument Panel Junction Block Assembly)
|
-
|
-
|
(b) Disconnect the 4B instrument panel junction block assembly connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
4B-26 - MB-29 (SH)
|
Always
|
Below 1 Ω
|
OK
|
|
|
5.
|
CHECK HARNESS AND CONNECTOR (BATTERY - S-HORN RELAY)
|
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
No. 3 relay block assembly S-HORN relay terminal 1 - Body ground
|
Always
|
11 to 14 V
|
No. 3 relay block assembly S-HORN relay terminal 5 - Body ground
|
Always
|
11 to 14 V
|
|
|
*1
|
No. 3 Relay Block Assembly
|
|
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
6.
|
CHECK HARNESS AND CONNECTOR (S-HORN RELAY - SECURITY HORN ASSEMBLY AND BODY GROUND)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
No. 3 relay block assembly S-HORN relay terminal 3 - A16-1
|
Always
|
Below 1 Ω
|
No. 3 relay block assembly S-HORN relay terminal 3 or A16-1 - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
|
|
*1
|
No. 3 Relay Block Assembly
|
|
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
7.
|
CHECK HARNESS AND CONNECTOR (S-HORN RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY AND BODY GROUND)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
No. 3 relay block assembly S-HORN relay terminal 2 - 4B-26
|
Always
|
Below 1 Ω
|
No. 3 relay block assembly S-HORN relay terminal 2 or 4B-26 - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
|
|
*1
|
No. 3 Relay Block Assembly
|
|
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|