Last Modified: 05-13-2024 |
6.11:8.1.0 |
Doc ID: RM100000001HCAO |
Model Year Start: 2020 |
Model: Corolla Hatchback |
Prod Date Range: [01/2019 - 03/2019] |
Title: M20A-FKS (COOLING): FLOW SHUTTING VALVE (for CVT): REMOVAL; 2020 MY Corolla Corolla Hatchback [01/2019 - 03/2019] |
REMOVAL
CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during flow shutting valve (water valve) removal/installation are shown below.
Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure
|
Necessary Procedure
|
Effect/Inoperative Function when Necessary Procedure not Performed
|
Link
|
Battery terminal is disconnected/reconnected
|
Perform steering sensor zero point calibration
|
Lane Control System
|
|
Pre-collision system
|
Lighting System (w/ AFS)(EXT)
|
Initialize back door lock*1
|
Power door lock control system
|
|
NOTICE:
-
After the ignition switch is turned off, the radio and display receiver assembly records various types of memory and settings. As a result, after turning the ignition switch off, make sure to wait at least 85 seconds before disconnecting the cable from the negative (-) battery terminal. (for Audio and Visual System (for Gasoline Model))
-
After the engine switch is turned off, the radio and display receiver assembly records various types of memory and settings. As a result, after turning the engine switch off, make sure to wait at least 85 seconds before disconnecting the cable from the negative (-) battery terminal. (for Navigation System)
PROCEDURE
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Click here
2. REMOVE NO. 1 ENGINE UNDER COVER ASSEMBLY
Click here
3. DRAIN ENGINE COOLANT
Click here
4. REMOVE FLOW SHUTTING VALVE (WATER VALVE)
(a) Disconnect the flow shutting valve (water valve) connector.
|
|
(b) Remove the bolt to disconnect the flow shutting valve (water valve).
|
|
(c) Slide the clip and disconnect the No. 3 water by-pass hose from the flow shutting valve (water valve).
|
|
(d) Slide the clip and disconnect the No. 4 water by-pass hose from the flow shutting valve (water valve).
|
|
|