Last Modified: 05-13-2024 |
6.11:8.1.0 |
Doc ID: RM100000001H981 |
Model Year Start: 2020 |
Model: Corolla |
Prod Date Range: [01/2019 - 09/2022] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): Air Vent cannot be Switched; 2020 - 2022 MY Corolla Corolla HV [01/2019 - 09/2022] |
Air Vent cannot be Switched
|
DESCRIPTION
If the air outlet mode does not change even though the air outlet display changes, the following factors may be the cause.
Symptom
|
Factor
|
Air outlet mode cannot be changed
-
(Air outlet display changes)
|
-
No. 1 air conditioning radiator damper servo sub-assembly malfunction
-
No. 2 air conditioning radiator damper servo sub-assembly malfunction*
-
No. 3 air conditioning radiator damper servo sub-assembly malfunction
-
Damper link disconnection
-
Air conditioner unit assembly malfunction
|
PROCEDURE
(a) Choose the model to be inspected.
Result
|
Proceed to
|
except Cold Area Spec.
|
A
|
for Cold Area Spec.
|
B
|
A
|
|
|
2.
|
CHECK AIR OUTLET SERVO MOTOR
|
(a) Confirm for which seat the air outlet mode cannot be changed.
Result
|
Proceed to
|
The air outlet mode for the driver seat cannot be changed
|
A
|
The air outlet mode for the front passenger seat cannot be changed
|
B
|
3.
|
CHECK AIR OUTLET SERVO MOTOR
|
(a) Confirm for which seat the air outlet mode cannot be changed.
Result
|
Proceed to
|
The air outlet mode for the driver seat cannot be changed
|
A
|
The air outlet mode for the front passenger seat cannot be changed
|
B
|
The air outlet mode for the rear seats cannot be changed
|
C
|
A
|
|
|
4.
|
CHECK NO. 3 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
|
(a) Check that the No. 3 air conditioning radiator damper servo sub-assembly is installed correctly.
OK:
The No. 3 air conditioning radiator damper servo sub-assembly is installed correctly.
OK
|
|
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Trouble Codes.
(e) Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
|
Proceed to
|
B1443 is not output
|
A
|
B1443 is output
|
B
|
6.
|
CHECK NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
|
(a) Check that the No. 1 air conditioning radiator damper servo sub-assembly is installed correctly.
OK:
The No. 1 air conditioning radiator damper servo sub-assembly is installed correctly.
OK
|
|
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Trouble Codes.
(e) Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
|
Proceed to
|
B1448 is not output
|
A
|
B1448 is output
|
B
|
8.
|
CHECK NO. 2 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
|
(a) Check that the No. 2 air conditioning radiator damper servo sub-assembly is installed correctly.
OK:
The No. 2 air conditioning radiator damper servo sub-assembly is installed correctly.
OK
|
|
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Trouble Codes.
(e) Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
|
Proceed to
|
B1449 is not output
|
A
|
B1449 is output
|
B
|
|