Last Modified: 07-31-2024 6.11:8.1.0 Doc ID: RM100000001H980
Model Year Start: 2020 Model: Corolla Prod Date Range: [01/2019 - 09/2022]
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): No Cool Air Comes Out; 2020 - 2022 MY Corolla Corolla HV [01/2019 - 09/2022]

No Cool Air Comes Out

DESCRIPTION

If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.

Symptom

Factor

No cool air comes out

  • (Blower control is normal)
  • Compressor with motor assembly malfunction
  • Refrigerant pressure is extremely high or low
  • Refrigerant volume (low)
  • Clogged cooler condenser assembly fins
  • Cooling fan system malfunction
  • Mechanical locking of damper and damper link
  • No. 1 cooler thermistor malfunction
  • High inlet air temperature

PROCEDURE

1.

CHECK SWITCH INDICATOR

(a) Operate each switch on the air conditioning control assembly and check that the switch indicators operate normally.

OK:

All switch indicators operate normally.

NG

GO TO OTHER DIAGNOSIS PROCEDURE (Operation not Accepted Even If Air Conditioning Switch is Operated)

OK

2.

PERFORM ACTIVE TEST USING TECHSTREAM

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Turn the Techstream on.

(d) Enter the following menus: Body Electrical / Air Conditioner / Active Test.

(e) Perform the Active Test according to the display on the Techstream.

Body Electrical > Air Conditioner > Active Test

Tester Display

Measurement Item

Control Range

Diagnostic Note

Air Mix Servo Targ Pulse(D)

No. 1 air conditioning radiator damper servo sub-assembly pulse

Min.: 128

Max.: 383

Operates between 165 and 257 pulses

Body Electrical > Air Conditioner > Active Test

Tester Display

Air Mix Servo Targ Pulse(D)

OK:

The No. 1 air conditioning radiator damper servo motor operates.

OK

INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

for HFC-134a (R134a): Click here 2020 - 2025 MY Corolla Corolla Hatchback Corolla HV GR Corolla [01/2019 -        ]; HEATING / AIR CONDITIONING: REFRIGERANT (for HFC-134a(R134a)): ON-VEHICLE INSPECTION

for HFO-1234yf (R1234yf): Click here 2020 - 2025 MY Corolla Corolla Hatchback Corolla HV GR Corolla [01/2019 -        ]; HEATING / AIR CONDITIONING: REFRIGERANT (for HFO-1234yf(R1234yf)): ON-VEHICLE INSPECTION

NG

GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR 2020 MY Corolla Corolla HV [01/2019 - 04/2020]; HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): DIAGNOSTIC TROUBLE CODE CHART 2021 - 2022 MY Corolla Corolla HV [04/2020 - 09/2022]; HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): DIAGNOSTIC TROUBLE CODE CHART