TERMINALS OF ECU

NOTICE:

  • Turning the power switch on (IG) with connectors disconnected may cause DTCs to be stored. Make sure to clear the DTCs after inspection has been performed.
  • Do not apply excessive force to the millimeter wave radar sensor assembly connector.

CHECK MILLIMETER WAVE RADAR SENSOR ASSEMBLY

(a) Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol)

Wiring Color

Terminal Description

Condition

Specified Condition

A1-8 (IGB) - A1-1 (SGND)

R - W-B

Power source

Power switch on (IG)

11 to 14 V

Power switch off

Below 1 V

A1-1 (SGND) - Body ground

W-B - Body ground

Ground

Always

Below 1 Ω

(b) Check for pulses according to the value(s) in the table below.

HINT:

If the waveform is not similar to that shown in the illustration, a malfunction of a CAN bus line, terminating resistor, or the millimeter wave radar sensor assembly is suspected.

Terminal No. (Symbol)

Wiring Color

Terminal Description

Condition

Specified Condition

A1-5 (CA1P) - A1-1 (SGND)

LG - W-B

CAN communication signal

Power switch on (IG)

Pulse generation

(See waveform 1)

A1-6 (CA1N) - A1-1 (SGND)

V - W-B

Pulse generation

(See waveform 2)

A1-3 (CA2H) - A1-1 (SGND)

W - W-B

Pulse generation

(See waveform 1)

A1-2 (CA2L) - A1-1 (SGND)

B - W-B

Pulse generation

(See waveform 2)

(1) WAVEFORM 1

Item

Content

Tester Connection

  • Between A1-5 (CA1P) and A1-1 (SGND)
  • Between A1-3 (CA2H) and A1-1 (SGND)

Tool Setting

1 V/DIV., 10 μs/DIV.

Condition

Power switch on (IG)

HINT:

The waveform varies depending on the CAN communication signal.

(2) WAVEFORM 2

Item

Content

Tester Connection

  • Between A1-6 (CA1N) and A1-1 (SGND)
  • Between A1-2 (CA2L) and A1-1 (SGND)

Tool Setting

1 V/DIV., 10 μs/DIV.

Condition

Power switch on (IG)

HINT:

The waveform varies depending on the CAN communication signal.