Either of the following:
-
The problem symptom is that of Problem Symptom Pattern B and the suspected area is in Bus 1.
-
Resistance between CAN bus lines (CANH and CANL) in Bus 1 is 70 Ω or more.
|
Open in Bus 1 Main Bus Line
|
|
Either of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short between CAN bus lines (CANH and CANL) in Bus 1 is suspected.
-
Resistance between CAN bus lines (CANH and CANL) in Bus 1 is below 54 Ω.
|
Short in Bus 1 Lines
|
|
Any of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short to +B in a CAN bus line (CANH or CANL) in Bus 1 is suspected.
-
Resistance between CANH and +B in Bus 1 is below 6 kΩ.
-
Resistance between CANL and +B in Bus 1 is below 6 kΩ.
|
Short to +B in Bus 1 Line
|
|
Any of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short to ground in a CAN bus line (CANH or CANL) in Bus 1 is suspected.
-
Resistance between CANH and ground in Bus 1 is below 200 Ω.
-
Resistance between CANL and ground in Bus 1 is below 200 Ω.
|
Short to GND in Bus 1 Line
|
|
Resistance between CANH and CANL is normal in Bus 1 and the problem symptom pattern in How to Use "Communication Bus Check" Screen in Inspection matches the symptoms when there is an open in one wire of a branch line in Bus 1.
|
Open in One Side of Bus 1 Branch Line
|
|
Either of the following:
-
The problem symptom is that of Problem Symptom Pattern B and the suspected area is in Bus 2.
-
Resistance between CAN bus lines (CANH and CANL) in Bus 2 is 70 Ω or more.
|
Open in Bus 2 Main Bus Line
|
|
Either of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short between CAN bus lines (CANH and CANL) in Bus 2 is suspected.
-
Resistance between CAN bus lines (CANH and CANL) in Bus 2 is below 54 Ω.
|
Short in Bus 2 Lines
|
|
Any of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short to +B in a CAN bus line (CANH or CANL) in Bus 2 is suspected.
-
Resistance between CANH and +B in Bus 2 is below 6 kΩ.
-
Resistance between CANL and +B in Bus 2 is below 6 kΩ.
|
Short to +B in Bus 2 Line
|
|
Any of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short to ground in a CAN bus line (CANH or CANL) in Bus 2 is suspected.
-
Resistance between CANH and ground in Bus 2 is below 200 Ω.
-
Resistance between CANL and ground in Bus 2 is below 200 Ω.
|
Short to GND in Bus 2 Line
|
|
Resistance between CANH and CANL is normal in Bus 2 and the problem symptom pattern in How to Use "Communication Bus Check" Screen in Inspection matches the symptoms when there is an open in one wire of a branch line in Bus 2.
|
Open in One Side of Bus 2 Branch Line
|
|
Either of the following:
-
The problem symptom is that of Problem Symptom Pattern B and the suspected area is in Bus 3.
-
Resistance between CAN bus lines (CANH and CANL) in Bus 3 is 70 Ω or more.
|
Open in Bus 3 Main Bus Line
|
|
Either of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short between CAN bus lines (CANH and CANL) in Bus 3 is suspected.
-
Resistance between CAN bus lines (CANH and CANL) in Bus 3 is below 54 Ω.
|
Short in Bus 3 Lines
|
|
Any of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short to +B in a CAN bus line (CANH or CANL) in Bus 3 is suspected.
-
Resistance between CANH and +B in Bus 3 is below 6 kΩ.
-
Resistance between CANL and +B in Bus 3 is below 6 kΩ.
|
Short to +B in Bus 3 Line
|
|
Any of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short to ground in a CAN bus line (CANH or CANL) in Bus 3 is suspected.
-
Resistance between CANH and ground in Bus 3 is below 200 Ω.
-
Resistance between CANL and ground in Bus 3 is below 200 Ω.
|
Short to GND in Bus 3 Line
|
|
Resistance between CANH and CANL is normal in Bus 3 and the problem symptom pattern in How to Use "Communication Bus Check" Screen in Inspection matches the symptoms when there is an open in one wire of a branch line in Bus 3.
|
Open in One Side of Bus 3 Branch Line
|
|
Either of the following:
-
The problem symptom is that of Problem Symptom Pattern B and the suspected area is in Bus 4.
-
Resistance between CAN bus lines (CANH and CANL) in Bus 4 is 70 Ω or more.
|
Open in Bus 4 Main Bus Line
|
|
Either of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short between CAN bus lines (CANH and CANL) in Bus 4 is suspected.
-
Resistance between CAN bus lines (CANH and CANL) in Bus 4 is below 54 Ω.
|
Short in Bus 4 Lines
|
|
Any of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short to +B in a CAN bus line (CANH or CANL) in Bus 4 is suspected.
-
Resistance between CANH and +B in Bus 4 is below 6 kΩ.
-
Resistance between CANL and +B in Bus 4 is below 6 kΩ.
|
Short to +B in Bus 4 Line
|
|
Any of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short to ground in a CAN bus line (CANH or CANL) in Bus 4 is suspected.
-
Resistance between CANH and ground in Bus 4 is below 200 Ω.
-
Resistance between CANL and ground in Bus 4 is below 200 Ω.
|
Short to GND in Bus 4 Line
|
|
Resistance between CANH and CANL is normal in Bus 4 and the problem symptom pattern in How to Use "Communication Bus Check" Screen in Inspection matches the symptoms when there is an open in one wire of a branch line in Bus 4.
|
Open in One Side of Bus 4 Branch Line
|
|
Either of the following:
-
The problem symptom is that of Problem Symptom Pattern B and the suspected area is in Bus 5.
-
Resistance between CAN bus lines (CANH and CANL) in Bus 5 is 70 Ω or more.
|
Open in Bus 5 Main Bus Line
|
|
Either of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short between CAN bus lines (CANH and CANL) in Bus 5 is suspected.
-
Resistance between CAN bus lines (CANH and CANL) in Bus 5 is below 54 Ω.
|
Short in Bus 5 Lines
|
|
Any of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short to +B in a CAN bus line (CANH or CANL) in Bus 5 is suspected.
-
Resistance between CANH and +B in Bus 5 is below 6 kΩ.
-
Resistance between CANL and +B in Bus 5 is below 6 kΩ.
|
Short to +B in Bus 5 Line
|
|
Any of the following:
-
The problem symptom is similar to that of Problem Symptom Pattern A and a short to ground in a CAN bus line (CANH or CANL) in Bus 5 is suspected.
-
Resistance between CANH and ground in Bus 5 is below 200 Ω.
-
Resistance between CANL and ground in Bus 5 is below 200 Ω.
|
Short to GND in Bus 5 Line
|
|
Resistance between CANH and CANL is normal in Bus 5 and the problem symptom pattern in How to Use "Communication Bus Check" Screen in Inspection matches the symptoms when there is an open in one wire of a branch line in Bus 5.
|
Open in One Side of Bus 5 Branch Line
|
|