Last Modified: 05-13-2024 |
6.11:8.1.0 |
Doc ID: RM100000001GCOU |
Model Year Start: 2020 |
Model: Corolla |
Prod Date Range: [01/2019 - 09/2022] |
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P0E0012,...,P0E081F; Generator Phase U Current Sensor Circuit Short to Battery; 2020 - 2022 MY Corolla Corolla HV [01/2019 - 09/2022] |
DTC
|
P0E0012
|
Generator Phase U Current Sensor Circuit Short to Battery
|
DTC
|
P0E0014
|
Generator Phase U Current Sensor Circuit Short to Ground or Open
|
DTC
|
P0E001F
|
Generator Phase U Current Sensor Circuit Intermittent
|
DTC
|
P0E0412
|
Generator Phase V Current Sensor Circuit Short to Battery
|
DTC
|
P0E0414
|
Generator Phase V Current Sensor Circuit Short to Ground or Open
|
DTC
|
P0E041F
|
Generator Phase V Current Sensor Circuit Intermittent
|
DTC
|
P0E0812
|
Generator Phase W Current Sensor Circuit Short to Battery
|
DTC
|
P0E0814
|
Generator Phase W Current Sensor Circuit Short to Ground or Open
|
DTC
|
P0E081F
|
Generator Phase W Current Sensor Circuit Intermittent
|
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:
Internal inverter malfunction
-
Inverter with converter assembly internal circuit malfunction
Inverter low-voltage circuit malfunction
-
The connectors are not connected properly
DESCRIPTION
The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors the generator inverter current sensor. These DTCs indicate the malfunction of current sensors and do not indicate a malfunction of the high-voltage system.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P0E0012
|
Generator Phase U Current Sensor Circuit Short to Battery
|
Malfunction in generator inverter current sensor (phase U main sensor)
(Short to +B)
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Comes on
|
Master Warning:
Comes on
|
P0E0014
|
Generator Phase U Current Sensor Circuit Short to Ground or Open
|
Malfunction in generator inverter current sensor (phase U main sensor)
(Open or short to ground)
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Comes on
|
Master Warning:
Comes on
|
P0E001F
|
Generator Phase U Current Sensor Circuit Intermittent
|
Short to +B, open or short to ground detected in generator inverter current sensor (phase U main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Does not come on
|
Master Warning:
Does not come on
|
P0E0412
|
Generator Phase V Current Sensor Circuit Short to Battery
|
Malfunction in generator inverter current sensor (phase V main sensor)
(Short to +B)
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Comes on
|
Master Warning:
Comes on
|
P0E0414
|
Generator Phase V Current Sensor Circuit Short to Ground or Open
|
Malfunction in generator inverter current sensor (phase V main sensor)
(Open or short to ground)
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Comes on
|
Master Warning:
Comes on
|
P0E041F
|
Generator Phase V Current Sensor Circuit Intermittent
|
Short to +B, open or short to ground detected in generator inverter current sensor (phase V main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Does not come on
|
Master Warning:
Does not come on
|
P0E0812
|
Generator Phase W Current Sensor Circuit Short to Battery
|
Malfunction in generator inverter current sensor (phase W main sensor)
(Short to +B)
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Comes on
|
Master Warning:
Comes on
|
P0E0814
|
Generator Phase W Current Sensor Circuit Short to Ground or Open
|
Malfunction in generator inverter current sensor (phase W main sensor)
(Open or short to ground)
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Comes on
|
Master Warning:
Comes on
|
P0E081F
|
Generator Phase W Current Sensor Circuit Intermittent
|
Short to +B, open or short to ground detected in generator inverter current sensor (phase W main sensor) when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Wire harness or connector
|
Does not come on
|
Master Warning:
Does not come on
|
MONITOR DESCRIPTION
The motor generator control ECU monitors the generator inverter current sensor. If the motor generator control ECU detects a malfunction, it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs
|
P0E03 (INF P0E0012): Generator Phase U Current Sensor Range check (High voltage)
P0E02 (INF P0E0014): Generator Phase U Current Sensor Range check (Low voltage)
P0E07 (INF P0E0412): Generator Phase V Current Sensor Range check (High voltage)
P0E06 (INF P0E0414): Generator Phase V Current Sensor Range check (Low voltage)
P0E0B (INF P0E0812): Generator Phase W Current Sensor Range check (High voltage)
P0E0A (INF P0E0814): Generator Phase W Current Sensor Range check (Low voltage)
|
Required sensors/components
|
Generator phase U current sensor
Generator phase V current sensor
Generator phase W current sensor
|
Frequency of operation
|
Continuous
|
Duration
|
TMC's intellectual property
|
MIL operation
|
Immediately
|
Sequence of operation
|
None
|
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored
|
TMC's intellectual property
|
Other conditions belong to TMC's intellectual property
|
-
|
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property
|
-
|
COMPONENT OPERATING RANGE
Motor generator control ECU
|
DTC P0E03 (INF P0E0012) is not detected
DTC P0E02 (INF P0E0014) is not detected
DTC P0E07 (INF P0E0412) is not detected
DTC P0E06 (INF P0E0414) is not detected
DTC P0E0B (INF P0E0812) is not detected
DTC P0E0A (INF P0E0814) is not detected
|
CONFIRMATION DRIVING PATTERN
HINT:
-
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
With power switch on (IG) and wait for 5 seconds or more. [*1]
-
Turn the power switch on (READY) with the shift lever in P and wait for 5 seconds or more. [*2]
-
Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine. [*3]
-
Drive the vehicle forward with the shift lever in D and drive the vehicle forward for 5 m (16 ft.) or more. [*4]
-
Drive the vehicle backward with the shift lever in R and drive the vehicle backward for 5 m (16 ft.) or more. [*5]
HINT:
[*1] to [*5]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
-
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
CAUTION / NOTICE / HINT
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
PROCEDURE
1.
|
CHECK DTC OUTPUT (MOTOR GENERATOR CONTROL)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Motor Generator > Trouble Codes
Result
|
Proceed to
|
P0E0012, P0E0014, P0E001F, P0E0412, P0E0414, P0E041F, P0E0812, P0E0814 and P0E081F only is output, or DTCs except the ones in the table below are also output.
|
A
|
Any of the following DTCs including pending DTCs are also output.
|
B
|
Malfunction Content
|
Relevant DTC
|
Power source circuit malfunction
|
P06B01C
|
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
P06D61C
|
Generator Control Module Offset Power Circuit Voltage Out of Range
|
System malfunction
|
P0A7A73
|
Generator Inverter Actuator Stuck Closed
|
HINT:
-
P0E0012, P0E0014, P0E001F, P0E0412, P0E0414, P0E041F, P0E0812, P0E0814 and P0E081F may be output as a result of the malfunction indicated by the DTCs above.
-
The chart above is listed in inspection order of priority.
-
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
A
|
|
|
2.
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
|
Click here
Result
|
Proceed to
|
OK
|
A
|
NG (The connector is not connected securely.)
|
B
|
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.)
|
C
|
B |
|
CONNECT SECURELY
|
C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|