P060647
|
Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure
|
ECU internal malfunction
(HV-CPU error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P060687
|
Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message
|
ECU internal malfunction
(Communication error (main to sub CPU))
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P060A29
|
Hybrid/EV Powertrain Control Module Monitoring Processor Signal Invalid
|
ECU internal malfunction
(Sub CPU circuit error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P060A44
|
Hybrid/EV Powertrain Control Module Monitoring Processor Data Memory Failure
|
ECU internal malfunction
(Sub CPU RAM error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P060A45
|
Hybrid/EV Powertrain Control Module Monitoring Processor Program Memory Failure
|
ECU internal malfunction
(Sub CPU ROM error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P060A47
|
Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure
|
ECU internal malfunction
(Sub CPU WDC error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P060A49
|
Hybrid/EV Powertrain Control Module Monitoring Processor Internal Electronic Failure
|
ECU internal malfunction
(Sub CPU calculation check error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P060A87
|
Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message
|
ECU internal malfunction
(Communication error (sub to main CPU))
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P060B1C
|
Hybrid/EV Powertrain Control Module A/D Processing Voltage Out of Range
|
ECU internal malfunction
(AD conversion error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P060B49
|
Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure
|
ECU internal malfunction
(AD timeout error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P060B71
|
Hybrid/EV Powertrain Control Module A/D Processing Actuator Stuck
|
ECU internal malfunction
(AD multiplexer error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P1C9E9F
|
Hybrid/EV System Reset Stuck Off
|
ECU internal malfunction
(Primary check error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P1CE31C
|
Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Voltage Out of Range
|
ECU internal malfunction
(Sub CPU AD conversion error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P1CE349
|
Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Internal Electronic Failure
|
ECU internal malfunction
(Sub CPU AD timeout error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|
P1CE371
|
Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Actuator Stuck
|
ECU internal malfunction
(Sub CPU AD multiplexer error)
(1 trip detection logic)
|
Hybrid vehicle control ECU
|
Comes on
|
Master Warning: Comes on
|