(2) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Float Level
|
Specified Condition
|
1 - 2
|
F
|
4.255 to 4.605 V*
|
Between F and E
|
0.345 to 4.605 V* (Gradually changes)
|
E
|
0.345 to 0.695 V*
|
*: The output voltage changes depending on the voltage applied to the terminals.
Output voltage (F) = (0.851 x Voltage applied to terminals) to (0.921 x Voltage applied to terminals)
Output voltage (E) = (0.069 x Voltage applied to terminals) to (0.139 x Voltage applied to terminals)
If the result is not as specified, replace the fuel sender gauge assembly.
|