(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Specified Condition
|
U - V
|
0.05 to 3.0 Ω
|
V - W
|
0.05 to 3.0 Ω
|
U - W
|
0.05 to 3.0 Ω
|
If the result is not as specified, replace the fuel pump.
|
|
*a
|
Component without harness connected
(Fuel Pump)
|
|
|