Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM100000001CZTF |
Model Year Start: 2019 |
Model: Corolla Hatchback |
Prod Date Range: [06/2018 - 09/2019] |
Title: M20A-FKS (COOLING): FLOW SHUTTING VALVE (for CVT): INSTALLATION; 2019 - 2020 MY Corolla Corolla Hatchback [06/2018 - 09/2019] |
INSTALLATION
PROCEDURE
1. INSTALL FLOW SHUTTING VALVE (WATER VALVE)
(a) Connect the No. 4 water by-pass hose to the flow shutting valve (water valve) and slide the clip to secure it.
*a
|
2 to 5 mm (0.0787 to 0.197 in.)
|
*b
|
Paint Mark
|
*c
|
45° (Tabs of Clip Installation Area)
|
*d
|
protrusion
|
NOTICE:
-
Make sure to align the paint mark of the No. 4 water by-pass hose with the protrusion of the flow shutting valve (water valve).
-
Make sure to slide the No. 4 water by-pass hose until it contacts the hose stopper of the flow shutting valve (water valve).
-
Make sure that the tabs of the clip are within the area shown in the illustration.
(b) Connect the No. 3 water by-pass hose to the flow shutting valve (water valve) and slide the clip to secure it.
*a
|
2.0 to 7.0 mm (0.0787 to 0.276 in.)
|
*b
|
Paint Mark
|
*c
|
60° (Tabs of Clip Installation Area)
|
*d
|
protrusion
|
NOTICE:
-
Make sure to align the paint mark of the No. 3 water by-pass hose with the protrusion of the flow shutting valve (water valve).
-
Make sure to slide the No. 3 water by-pass hose until it contacts the hose stopper of the flow shutting valve (water valve).
-
Make sure that the tabs of the clip are within the area shown in the illustration.
(c) Connect the flow shutting valve (water valve) with the bolt.
Torque:
19 N·m {194 kgf·cm, 14 ft·lbf}
(d) Connect the flow shutting valve (water valve) connector.
2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Click here
3. ADD ENGINE COOLANT
Click here
4. INSPECT FOR COOLANT LEAK
Click here
5. INSTALL NO. 1 ENGINE UNDER COVER ASSEMBLY
Click here
|