Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM100000001CZTA |
Model Year Start: 2019 |
Model: Corolla Hatchback |
Prod Date Range: [06/2018 -
] |
Title: M20A-FKS (COOLING): FLOW SHUTTING VALVE (for Heater): INSPECTION; 2019 - 2025 MY Corolla Corolla Hatchback [06/2018 - ] |
INSPECTION
PROCEDURE
1. INSPECT FLOW SHUTTING VALVE (WATER VALVE)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 - 2
|
20°C (68°F)
|
22 to 28 Ω
|
If the result is not as specified, replace the flow shutting valve (water valve).
|