(1) Apply auxiliary battery voltage to the light control rheostat switch and check that it illuminates.
OK:
Condition
|
Specified Condition
|
Auxiliary battery positive (+) → Terminal 6 (ILL+)
Auxiliary battery negative (-) → Terminal 1 (ILL-)
|
Illuminates
|
If the result is not as specified, replace the light control rheostat switch.
|
|
*a
|
Component without harness connected
(Light Control Rheostat Switch)
|
|
|