Last Modified: 07-31-2024 |
6.11:8.1.0 |
Doc ID: RM100000001CO0N |
Model Year Start: 2019 |
Model: GR Corolla |
Prod Date Range: [06/2018 - 01/2019] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System): Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting); 2019 MY Corolla Corolla Hatchback GR Corolla [06/2018 - 01/2019] |
Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting)
|
DESCRIPTION
If the temperature of the air that blows from the left and right front registers differs, even though the same temperature is set for both sides, the following factors may be the cause.
Symptom
|
Factor
|
Temperature of outlet air is cooler on left or right side (when same temperature set for both sides)
|
-
Compressor assembly with pulley malfunction
-
Refrigerant volume (low)
-
Mechanical locking of damper and damper link
-
Automatic light control sensor malfunction
-
Harness or connector
|
Temperature of outlet air is warmer on left or right side (when same temperature set for both sides)
|
-
Mechanical locking of damper and damper link
-
Blockage in heater radiator unit sub-assembly
-
Harness or connector
|
CAUTION / NOTICE / HINT
NOTICE:
The air conditioning system uses the CAN communication system. Inspect the communication functions by following How to Proceed with Troubleshooting. Troubleshoot the air conditioning system after confirming that the communication systems are functioning properly.
Click here
PROCEDURE
1.
|
CHECK WHEN MALFUNCTION OCCURS
|
Result
|
Proceed to
|
When using cooling function
|
A
|
When using heater function
|
B
|
A
|
|
|
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Main Body / Trouble Codes.
(e) Check for DTCs.
Body Electrical > Main Body > Trouble Codes
Result
|
Proceed to
|
B1244 is not output
|
A
|
B1244 is output
|
B
|
B |
|
GO TO DTC B1244
w/o AFS: Click here
w/ AFS: Click here
|
A
|
|
|
3.
|
PERFORM REFRIGERANT SHORTAGE CHECK
|
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > Utility
Tester Display
|
Refrigerant Gas Volume Check
|
(e) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.
Measurement Condition:
Item
|
Condition
|
A/C switch
|
On
|
Ambient temperature*
|
0 to 49°C (32 to 120°F)
|
Blower speed
|
HI
|
*: If the ambient temperature is not within the range shown, do not perform this check.
Result
|
Amount of Refrigerant
|
Refrigerant correct
|
Correct
|
Refrigerant shortage
|
Insufficient
|
OK:
"Refrigerant correct" is displayed on the Techstream.
OK
|
|
|
4.
|
PERFORM ACTIVE TEST USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Active Test.
(e) Perform the Active Test according to the display on the Techstream.
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
Air Mix Servo Targ Pulse(D)
|
No. 1 air conditioning radiator damper servo sub-assembly pulse
|
Min.: 128
Max.: 383
|
Operates between 165 and 257 pulses
|
Air Mix Servo Targ Pulse(P)
|
No. 1 air conditioning radiator damper servo sub-assembly pulse
|
Min.: 128
Max.: 383
|
Operates between 165 and 257 pulses*
|
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Air Mix Servo Targ Pulse(D)
|
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Air Mix Servo Targ Pulse(P)
|
OK:
Each damper servo motor operates.
5.
|
BLEED AIR FROM COOLING SYSTEM
|
(a) Bleed air from cooling system.
Click here
NEXT
|
|
|
6.
|
CHECK OPERATION (AIR CONDITIONING SYSTEM)
|
(a) Set the same temperature for the left and right sides and check that the air that blows from the left and right front registers is the same temperature.
OK:
The air from the left and right front registers is the same temperature.
OK |
|
END (MALFUNCTION DUE TO AIR IN COOLING SYSTEM)
|
NG
|
|
|
7.
|
PERFORM ACTIVE TEST USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Active Test.
(e) Perform the Active Test according to the display on the Techstream.
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
Air Mix Servo Targ Pulse(D)
|
No. 1 air conditioning radiator damper servo sub-assembly pulse
|
Min.: 128
Max.: 383
|
Operates between 165 and 257 pulses
|
Air Mix Servo Targ Pulse(P)
|
No. 1 air conditioning radiator damper servo sub-assembly pulse
|
Min.: 128
Max.: 383
|
Operates between 255 and 347 pulses*
|
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Air Mix Servo Targ Pulse(D)
|
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Air Mix Servo Targ Pulse(P)
|
OK:
Each damper servo motor operates.
|